YASKAWA Z1000 Technical Manual page 450

Ac drive bypass for hvac fans and pumps 208 v: 1/2 to 100 hp 480 v: 3/4 to 250 hp
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

H.3 User Setting Table
No.
d3-01
Jump Frequency 1
d3-02
Jump Frequency 2
d3-03
Jump Frequency 3
d3-04
Jump Frequency Width
E1-01
Input Voltage Setting
E1-03
V/f Pattern Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E2-01
Motor Rated Current
E2-03
Motor No-Load Current
Multi-Function Digital Input Terminal S3 Function
H1-03
Selection
Multi-Function Digital Input Terminal S4 Function
H1-04
Selection
Multi-Function Digital Input Terminal S5 Function
H1-05
Selection
Multi-Function Digital Input Terminal S6 Function
H1-06
Selection
Multi-Function Digital Input Terminal S7 Function
H1-07
Selection
H2-01
Multi-Function Contact Output (Terminal M1-M2)
Multi-Function Contact Output 2 (Terminal M3-
H2-02
M4)
Multi-Function Contact Output 3 (Terminal M5-
H2-03
M6)
H3-01
Terminal A1 Signal Level Selection
H3-02
Terminal A1 Function Selection
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-09
Terminal A2 Signal Level Selection
H3-10
Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
H3-13
Analog Input Filter Time Constant
H3-14
Analog Input Terminal Enable Selection
H3-16
Terminal A1 Offset
H3-17
Terminal A2 Offset
Multi-Function Analog Output Terminal FM
H4-01
Monitor Selection
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-03
Multi-Function Analog Output Terminal FM Bias
Multi-Function Analog Output Terminal AM
H4-04
Monitor Selection
L1-01
Motor Overload Protection Selection
L1-02
Motor Overload Protection Time
L2-01
Momentary Power Loss Operation Selection
450
Name
Setting
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual
User
No.
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-05
Undervoltage Detection Level (Uv1)
L3-02
Stall Prevention Level during Acceleration
L3-03
Stall Prevention Limit during Acceleration
L3-04
Stall Prevention Selection during Deceleration
L3-06
Stall Prevention Level during Run
L3-11
Overvoltage Suppression Function Selection
L3-25
Load Inertia Ratio
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Fault Output Operation Selection
L5-03
Time to Continue Making Fault Restarts
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-13
Motor Underload Protection Selection
Motor Underload Protection Level at Minimum
L6-14
Frequency
L8-02
Overheat Alarm Level
L8-05
Input Phase Loss Protection Selection
L8-06
Input Phase Loss Detection Level
L8-07
Output Phase Loss Protection
L8-09
Output Ground Fault Detection Selection
L8-38
Carrier Frequency Reduction Selection
n1-01
Hunting Prevention Selection
n1-02
Hunting Prevention Gain Setting
n3-04
High-Slip Braking Overload Time
n3-13
Overexcitation Deceleration Gain
o1-03
Digital Operator Display Selection
o1-09
Frequency Reference Display Units
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
o2-04
Drive Model Selection
o4-03
Cooling Fan Maintenance Operation Time Setting
o4-11
UB-9 to UB-16 Initialization
S1-01
Stillness Control Selection
S1-02
Voltage Reduction Rate
S1-03
Voltage Restoration Level
S1-04
Voltage Restoration Complete Level
S1-05
Voltage Restoration Sensitivity Time Constant
S1-06
Voltage Restoration Time Constant at Impact
S2-01
Sequence Timer 1 Start Time
S2-02
Sequence Timer 1 Stop Time
S2-03
Sequence Timer 1 Day Selection
S2-04
Sequence Timer 1 Selection
S2-05
Sequence Timer 1 Reference Source
Name
Setting
User