YASKAWA Z1000 Technical Manual page 369

Ac drive bypass for hvac fans and pumps 208 v: 1/2 to 100 hp 480 v: 3/4 to 250 hp
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

Object ID
AV13
AV14
Torque Reference (U1-09)
AV15
AV16
AV17
MF Output Status
AV18
AV19
PI Feedback Level
AV20
AV21
AV22
AV23
Bypass SW Num
AV24
Comm Error Detail
AV25
AV26
AV27
AV28
<1>
Parameter Number
AV29
<1>
AV30
AV31
AV32
120 V to Kx Coils
<2>
AV33
<3>
AV35
<3>
Output Freq In %
AV36
<3>
Output Freq In RPM
AV37
<3>
Torque Iq (U6-01)
AV38
<3>
Drive HOA Status
AV39
<3>
AV40
Last Drive Fault
<3>
AV41
Last Bypass Fault
<3>
Last Bypass Fault
AV41
<3>
AV42
<1>
Refer to Accessing Bypass Parameters and the Enter Command on page 374
listed in the analog or binary objects.
<2> Available in bypass controller software versions VST800298 and later.
<3> Available in bypass controller software versions VST800400 and later.
<4>
Refer to Fault Trace Contents on page 402
<5> Bypass fault is reported by its fault number. Example: This object will report a value of 3 when an FB03 - External Fault Bypass is present.
<6> Drive faults report the drive fault code.
10000. For example: This object will report a value of 10003 when an FB03 - External Fault Bypass is present.
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual
Modbus
Object Name
Address
Output Power
MF Input Status
002BH
Drive Status 2
002CH
002DH
DC Bus Voltage
PI Input Level
PI Output Level
003AH
Drive SW Num
004DH
003DH
KVA Setting
003EH
Control Method
Accel Time
Decel Time
Parameter Data
Motor Current
0x005C and
Drive kWH
0x005D
Drive Run Time
0x004C
0x003F
0x003E
0x0051
0x07DA first
<4>
0x0081
<5>
0x878C
0x878C
0080H (Drive
<6>
Fault Code
8788H (Bypass
for details.
Refer to Fault Trace Contents on page 402
Precision
XXXX.X
(for drives rated
above 11 kVA)
0047H
XXX.XX
(for drives rated
11 kVA or
lower)
0048H
XXXX.X
0031H
XXXXX
0038H
XXXX.X
0039H
XXXX.X
XXXX.X
XXXXX
8791H
XXXXX
XXXXX
0043H
XXXXX
0200H
XXXX.X
0201H
XXXX.X
XXXXX
XXXXX
8780H
XXXX.X
8790H
XXXXX
XXXXXXX.X
0.0 to 32767999.9
XXXX
XXX.XX
XXXX
XXX.X
X
digit
XX.XX
XXXX
XXXX
Fault)
or
XXXXX
Fault)
for an explanation of how to read and write drive parameters not
for details. Bypass faults report the bypass fault number +
C.6 BACnet Objects Supported
Range
Units
kW
%
Volts
%
%
%
0.0 to 6000.0
Sec
0.0 to 6000.0
Sec
0 to FFFFH
0 to FFFFH
Amps
Volts
kWH
-
Hours
-
%
-
RPM
-
%
-
-
-
-
-
-
-
-
-
-
PV Access
R
R
R
R
R
R
R
R
R
R
R
R
R
R
W
W
W
W
R
R
R
R
R
R
R
R
R
R
R
R
C
369