Cid Operation - Serial Remote Control - Comtec CDM-840 Installation And Operation Manual

Advanced vsat series remote router
Table of Contents

Advertisement

CDM-840 Remote Router
Appendix F
F.2.2
CID Operation – Serial Remote Control
Chapter 7. SERIAL-BASED REMOTE PRODUCT MANAGEMENT
The CDM-840's serial remote product management interface is an electrical interface that is
either an EIA-485 multi-drop bus (for the control of multiple devices) or an EIA-232 connection
(for the control of a single device). The interface uses ASCII characters in asynchronous serial
form to transmit data between the Controller (e.g., a User PC) and Target (e.g., the modem and
ODU). This data consists of control and status information, transmitted in packets of variable
length in accordance with the structure and protocol explained in detail in Chapter 7.
The Controller is in charge of the process of monitor and control, and is the only device that is
permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit
when they have been specifically instructed to do so by the Controller.
The exchange of information is transmitted, Controller-to-Target and Target-to-Controller, in
'packets'. Each packet contains a finite number of bytes consisting of printable ASCII characters,
excluding ASCII code 127 (DELETE).
In this context, the Carriage Return and Line Feed characters are considered printable. With one
exception, all messages from Controller-to-Target require a response – this will be either to return
data that has been requested by the Controller, or to acknowledge reception of an instruction to
change the configuration of the Target.
Start of Packet Target Address
<
ASCII Code 60
(1 character)
Packet "issued command" example:
Packet "issued query" example:
Start of Packet Target Address
>
ASCII Code 62
(1 character)
Packet example – response received for issued query: >0000/MSG=Comtech EF Data[cr][lf]
Controller-to-Target (Issued Command or Query)
Address
Delimiter
0000 (default)
/
ASCII Code 47
(4 characters)
(1 character)
Target-to-Controller (Response to Command or Query)
Address
Delimiter
0000 (default)
/
ASCII Code 47
(4 characters)
(1 character)
Instruction
Code Qualifier
Code
= or ?
ASCII Codes 61
or 63
(3 characters)
(1 character)
<0000/MSG=Comtech EF Data[cr]
<0000/MSG?[cr]
Instruction
Code Qualifier
Code
=, ?, !, *, #, ~
(ASCII Codes
61, 63, 33, 42,
35, or 126)
(3 characters)
(1 character)
F–6
MN-CDM840
Revision 3
Optional
End of Packet
Arguments
Carriage Return
ASCII Code 13
(n characters)
(1 character)
Optional
End of Packet
Arguments
Carriage Return
ASCII Code 13
(n characters)
(1 character)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents