Demodulator Status Commands And Queries - Comtec CDM-840 Installation And Operation Manual

Advanced vsat series remote router
Table of Contents

Advertisement

CDM-840 Remote Router
Serial-based Remote Product Management
7.3.4

Demodulator Status Commands and Queries

Command
Number of
Parameter
(Instruction
Arguments for
Type
Code
Command or
& Qualifier)
Response to Query
Rx Es/No
N/A
4 bytes
Rx Signal
N/A
5 bytes
Level
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Query only.
Returns the value of Es/No in the form xx.x, where:
xx.x=value, in dB, from -1 to -40 (negative sign (-) is implied) in 0.1 dB
increments.
NOTES:
1) The Es/No number correspond to the value that is displayed on HTTP
(via the Virtual Front Panel) or SNMP. This value is averaged in the
background for the previous 16 values.
2) For a faster Es/No reading use REN command.
EXAMPLE: <0/EBN?[cr]
RESPONSE NOTES:
1) Returns 99.9 if demod is unlocked.
2) Returns +040 for values greater than -40.0 dB.
Query only.
Returns the value of the Rx signal level, in dBm, in the form xxxxx, where:
xxxxx=value, in dBm, from -25 to -55 with a tolerance of ±5 dBm, in 0.5 dBm
increments.
EXAMPLE: <0/RSL?[cr]
RESPONSE NOTES:
1) If in the range of -25 to -55 dBm, returns RSL=-xx.y
2) If >-25 dBm, returns SL1=GT-25 (GT='greater than')
3) If <-55 dBm, returns SL1=LT-55 (LT='less than')
7–16
Response to
Query
Command
(Instruction
Response to Query
(Target to
Code &
(Target to Controller)
Controller)
Qualifier)
N/A
ESN?
ESN=xxxxx
(see Description of
Arguments)
N/A
RSL?
RSL=xxxxx
(see Description
of Arguments)