Redundancy Commands And Queries - Comtec CDM-840 Installation And Operation Manual

Advanced vsat series remote router
Table of Contents

Advertisement

CDM-840 Remote Router
Serial-based Remote Product Management
7.3.11

Redundancy Commands and Queries

Command
Number of
Parameter
(Instruction
Arguments for
Type
Code
Command or
& Qualifier)
Response to Query
Redundancy
N/A
1 byte
State
Force 1:1
FSW=
None
Switch
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Query only.
Returns the redundancy state of the unit in the form x, where:
0=Offline
1=Online
EXAMPLE: <0/RED?[cr]
>0000/RED=1[cr][lf]
Command only.
This command takes no arguments.
Forces the unit to toggle the Unit Fail relay to the "fail" state for approximately
500 ms.
NOTES:
1) If the unit is a 1:1 pair and it is currently the 'Online' unit, this forces a
switchover so the unit will then be in 'Standby' mode
2) The command is always executed by the unit regardless of whether it is
stand-alone, in a 1:1 pair, or part of a 1:N system.
EXAMPLE: <0/FSW=[cr]
7–30
Response to
Query
Command
(Instruction
Response to Query
(Target to
Code &
(Target to Controller)
Controller)
Qualifier)
N/A
RED?
RED=x
(see Description
of Arguments)
FSW=
N/A
N/A
FSW*
MN-CDM840
Revision 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents