Cleaning of the PC drum paper separator fingers

A. Periodically cleaning parts/cycle
• PC drum paper separator fingers: Every 40,000 prints
B. Procedure
1. Remove the cleaning blade.
See P.24
3.5.13

Cleaning of the Ds collars

A. Periodically cleaning parts/cycle
• Ds collars: Every 40,000 prints
B. Procedure
1. Divide the image unit into the PC drum assy and the developing assy.
See P.20
[1]
[1]
A09AF2C552DA
[1]
A09AF2C553DA
3. Periodical check
2. Using a soft cloth dampened with
alcohol, wipe the five paper separa-
tor fingers [1] clean of dirt.
2. Using a soft cloth dampened with
alcohol, wipe the two Ds collars [1]
clean of dirt.