16. Image quality problem
16.2.5
Image reading section: Black streaks or bands
A. Typical faulty images
B. Troubleshooting procedure
Step
1
Original glass is dirty, scratchy, worn, or damaged.
Shading sheet reading portion (the portion on the back-
2
side of the original glass to which original width scale is
affixed) is dirty.
3
Scanner mirrors are dirty, scratchy, or damaged.
4
Exposure lamp (LA1) is dirty.
CCD unit lens and CCD surface are dirty or scratchy.
5
<Check procedure>
Remove lens cover to check for possible contamination.
6
CCD board (CCDB) connector is loose.
7
MFP board (MFPB) connector is loose.
180
Black streaks
Check
Field Service Ver. 1.0 Apr. 2007
Black bands
Result
Action
YES
• Clean or change.
YES
• Clean.
YES
• Clean or change.
YES
• Clean or change.
YES
• Clean or change.
YES
• Reconnect.
YES
• Reconnect.
• Change CCD unit.
NO
• Change MFP board
(MFPB).