Konica Minolta BIZHUB 163 Service Manual page 153

Hide thumbs Also See for BIZHUB 163:
Table of Contents

Advertisement

10. Service Mode
E. ID ADJUST
Functions
• To set the image density by varying Vg and Vb on the engine side.
Use
• Used when the image density is high or low.
Setting/
• The default setting is 0.
Procedure
F. VG ADJUST
Functions
• To adjust image density by varying Vg with changing sensitivities as the PC drum is
used for an extended period of time.
Use
• Used when image problems (fog, void) occur.
• Used when the PC drum unit has been replaced.
Increase the setting value to eliminate void.
Decrease the setting value to eliminate fog.
Setting/
• The default setting is 0.
Procedure
G. FUSER TEMP. (PLAIN)
Functions
• To set the temperature of the fusing roller for each type of paper, thereby making up
for fusing performance that changes with the operating environment or type of paper.
Use
• Used when fusing failure occurs.
• Used when the type of paper is changed.
Setting/
• The default setting is 0.
Procedure
<Temperature table for adjusting fusing temperature for plain paper>
For bizhub 163
Setting value
Main scanning
251 mm or more
2
250 mm or less
251 mm or more
1
250 mm or less
251 mm or more
0 (default value)
250 mm or less
251 mm or more
-1
250 mm or less
118
Paper width
Sub scanning
direction
direction
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
361 mm or more
360 mm or less
Field Service Ver. 1.0 Apr. 2007
-3 to +3
-2 to +2
-1 to +2
Mode selected in SERVICE'S CHOICE
Mode 1
Fusing heater lamp temperature
200 °C
200 °C
200 °C
200 °C
200 °C
190 °C
190 °C
190 °C
180 °C
180 °C
180 °C
170 °C
Mode 3
190 °C
190 °C
185 °C
180 °C
180 °C
175 °C
170 °C
170 °C
165 °C
160 °C
160 °C
155 °C

Hide quick links: