Admin. Management - Konica Minolta BIZHUB 163 Service Manual

Hide thumbs Also See for BIZHUB 163:
Table of Contents

Advertisement

6. Utility Mode
6.3.2

ADMIN. MANAGEMENT

A. REMOTE MONITOR
Functions
• To set the access right when monitoring a user machine from a remote location on
the Service side.
Use
• RSD is used for remote monitoring.
Setting/
• The default setting is "LIMITED".
Procedure
• LIMITED: Access is prohibited. remote monitoring is disabled.
• LIMITED: Access right with limited functions. Detailed settings made in the user
machine can be monitored. It is, however, not possible to change the user setting or
upgrade firmware.
• FULL: Access right with no restrictions. In addition to being able to monitor the
detailed settings made in the user machine, the Service can change user settings
and upgrade firmware.
NOTE
• When [FULL] is selected, the [PASSWORD] screen will appear.
The Administrator of the user machine sets a 4-digit (0000 to 9999) password.
This password is necessary for remote monitoring and must be obtained in
advance from the administrator of the user machine.
NOTE
Precautions for Changing the Setting of [ADMIN. MANAGEMENT] - [REMOTE MONI-
TOR]
If the user machine setting has been changed from [LIMITED] to [FULL] or vice versa
while RSD (Remote Setup Diagnostic) communication is established, perform the
following operations:
• Temporarily disconnect the communication and re-execute [Remote Connect.]
• Press the Disconnect key to disconnect the communication.
• The specific changes made in the setting of REMOTE MONITOR are not validated
unless the connection is made again.
< Precautions for Using the RSD (Remote Setup Diagnostic)>
• When a connection is established with a local machine using the RSD, the follow-
ing message appears on the Display and no operations can be made from the con-
trol panel of the local machine. Neither the PC print nor Scanner function can be
accepted.
• No connection can be made with the RSD during operation from the control panel
of the local machine. Make the connection while no operations are performed on
the local machine.
20
OFF
"LIMITED"
Field Service Ver. 1.0 Apr. 2007
FULL
4980S533AB
A0CJF3C508DA