RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
Figure 7.2-11
Figure 7.2-12
Figure 7.2-13
To disassemble the input AUX / CSafe board
and the Hand sensor board:
1. Back off the 2 screws i, using a medium
Phillips screwdriver, to remove the input
AUX / CSafe board support.
2. Unplug the connectors indicated in the
figure, connected to the input AUX / CSafe
board.
3. Back off the 2 screws l to disassemble the
input AUX / CSafe board, using a small
Phillips screwdriver.
To disassemble the LCD:
1. Unplug the connectors of the cable coming
from keyboard, headphone jack, TTL board
and LCD (on the inverter), indicated in the
figure.
2. Back off the 8 screws indicated in the figure,
that are fixing the plate with the circuit
boards, to the front display covering.
3. Disconnect the cable coming from the TTL
board:
• Push open the clip fasteners of the
connector on the CPU board as shown in
the highlight;
• pull the cable out.
Continued on following page →