Technogym RECLINE EXCITE Service Maintenance Manual page 58

Table of Contents

Advertisement

Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
To speed up the troubleshooting procedure, check the state of the power indicator LEDs
on the various circuit boards.
(1)
Slightly lift up the Faston connectors on the machine power inlet socket. Place the tester
probes across the live and neutral pins on the same connector. The measured value should be
approximately 220 VAC or 110 VAC depending on the mains voltage.
(2)
As for step (1) but across pins 3 and 1 of connector CN3 on the brake board.
(3)
Using a tester, check that all the output voltages on connector CN1 of the brake board are
correct, referring to paragraph 2.8. "Cables".
(4)
As for step (3) but on connector CN7 of the display board.
(5)
As for step (3) but on connector CN7 of the digital plan board.
(6)
As for step (3) but on connector CN6 of the digital plan board.
(7)
As for step (3) but on connector CN1 of the LED board.
Page 6.10
RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3