9.3. SERVICE MENU CONFIGURATION

The configuration procedure is invoked when the machine is in standby mode, using a different
procedure for the 500 and 700 models.
• Accessing configuration of 500 models
Simultaneously press the ENTER, ↑, CLEAR keys. The following prompt appears on the LED
display:
To access the procedure, type in the password 2501 which protects against unauthorized access and
press "Enter" to confirm. To enter the password, increase or decrease the displayed value using the
↑ and ↓ keys, or use the +/- GOAL keys to scroll through and modify the individual digits.
At this point there are two options available:
Press numeric key ↑ to access the menu for configuring technical parameters; the machine display
will begin showing the current configuration, structured as in the diagram below:
• Accessing configuration of 700 models
Simultaneously press the keys 369. The following prompt appears on the display:
To access the procedure, type in the password 2501 which protects against unauthorized access and
press the "Enter" key to confirm. At this point there are two options available:
Press numeric key 1 to access the menu for configuring technical parameters; the machine display
will begin showing the current configuration, structured as in the diagram below:
Page 9.12
RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
ENTER PASSWORD:
↑ = Tech Config
↓ = Troubleshooting
ENTER PASSWORD:
1 = Tech Config
2 = Troubleshooting