Technogym RECLINE EXCITE Service Maintenance Manual page 60

Table of Contents

Advertisement

Replace the display
board
Replace the LED board
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
To speed up the troubleshooting procedure, check the state of the power indicator LEDs
on the various circuit boards.
Page 6.12
RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
A
YES
Are the DC v oltages at the
input to the display board
correct?
B
Are the DC v oltages at the
input to the digital plan
board correct?
Are the DC v oltages at the
output of the digital plan
board correct?
YES
Are the DC v oltages at the
input to the LED board
correct?
4
NO
5
NO
YES
6
NO
YES
7
NO
Replace cable CB-3
Replace cable CB-3
Replace the digital
plan board and/or the
386 board
Replace cable CBQ-11