9.3.3.
O
PERATING DATA
This function makes it possible to access the machine usage data stored in the low kit. To access
this menu, when the LED display shows:
press ENTER. This function is structured as follows:
In addition to the machine usage data, this function also includes the 2 sub-functions described
below:
9.3.3.1.
Read from low kit
To read the parameter values from the low kit memory and view them on the display, scroll using
the +/- keys until the LED display shows:
press ENTER to read the errors from the low kit, and return to the upper menu level by pressing
CLEAR for a few seconds.
9.3.3.2.
Write to low kit
To write the values of the currently displayed parameters to the low kit, scroll using the +/- keys
until the LED display shows:
press ENTER to write the new data to the low kit, and return to the upper menu level by pressing
CLEAR for a few seconds.
9.3.3.3.
Machine usage data
The machine usage data on the display is updated every 10 minutes. This means that, whenever the
machine is switched off, any data modified after the last memory update will be lost.
Page 9.16
OPERATING DATA
OPERATING DATA
READ FROM LOW KIT ?
WRITE TO LOW KIT ?
RECLINE EXCITE: Service & Maintenance Manual - rev. 1.3
READ FROM
LOW KIT ?
Life Brake
Life Kit H
Life Kit L
Tot. Km
WRITE TO
LOW KIT ?