Mounting The Expansion Key Service Unit - Toshiba strata DK8 Installation Instructions Manual

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-OK16 KSU & PCB
SECTION 100-816-205
MARCH 1993
4)
5)
'3)
7)
8)
9)
10)
11)
12)
13)
Secure screws approximately
two thirds of the
way into the top two holes on the mounting
surface.
Hang the unit from the top two screws
and
then secure
the screws
completely
into the
mounting
surface.
Finish securing
the unit to the mounting
sur-
face by completley
screwing
the bottom
two
screws into the wall.
Ground
system according
to Chapter
2, para-
graph 4.
Connect
applicable
wiring (modular
CO line
cords, 25pairamphenolconnectorcable,
etc.)
to the Base Key Service Unit and then fasten
wiring to the unit with the tie wrap that comes
with
the
base
unit
(Figure
5-4).
Remove
amphenol
connector
clamp from plastic bag
that comes
with the Base Unit. Fasten
the
clamp to hold the amphenol
connector.
Connect
Reserve
batteries
(per Paragraph
2.40) and plug battery
cable into BATT con-
nector of the KPSU16 power supply (Figure 5-
3 and 5-4).
Set the KCOU PAD switches (SW4OOSW475)
to the appropriate
position
(Figure
5-3). The
factory
setting
is NORMAL.
If CO lines are
connected
to a PBX or are in close proximity
to the central office the PAD position
may be
required.
If the Expansion
Key Service
Unit is going to
be installed, refer now to Paragraph
2.30. If not,
proceed
to Step 12.
Plug the AC power
cable
into an outlet and
then turn ON the power
supply switch.
Reinstall
the front and side covers
onto the
Base Key Service Unit.
2.30 Mounting the Expansion Key Service
Unit
1)
Make sure the side cover is removed
from the
12) Fasten the wiring with tie wraps (supplied)
to
Base Key Service
Unit. Turn Base Key Ser-
the bottom
of the Expansion
and Base Key
vice Unit DC power switch off.
Service Units (Figure
5-8).
2)
3)
4)
5)
6)
7)
8)
9)
Set the Expansion
Key Service
Unit on the
Base Key Service Unit's hinge mounts,
mak-
ing sure that the Expansion
Unit sets properly
in place (Figure
5-5).
Remove
safety
lock from plastic
bag which
comes with the Expansion
Unit. Install safety
lock to the Base Unit as shown
in Figure 5-5.
Pull out on the safety lock until it can no longer
be moved,
securing
the Expansion
Key Ser-
vice Unit to the Base Key Service Unit (Figure
5-5). Do not detach the lock from the Base Key
Service Unit.
Connect
the Expansion
Key Service Unit Rib-
bon Cable to the connector
on the Base Key
Service Unit (Figure 5-5). Close ribbon cable
connector
lock on Base Unit.
Connect
Expansion
Unit green/yellow
ground
wire plug (FG2) toTB1 of the Base Unit. (Make
sure the plug locks on TBl.)
See Figure 5-3
and 5-4.
Making
sure that the Expansion
Key Service
Unit is flush against
the mounting
surface,
mark
the
location
of the
Expansion
Unit
mounting
screw hole (Figure 5-6).
Swing the Expansion
Key Service
Unit away
from the mounting
surface,
and drill a hole at
the mark made in Step 7.
Install applicable
printed circuit boards (PCBs)
(see Chapter
5, Section
II)-after
PCBs are
installed,
slide the slot lock to the lock position
(Figure 5-7).
10) Swing the Expansion
Key Service Unit back to
the mounting
surface
and secure
it to the
surface
with a screw.
11) Connect
applicable
wiring
(modular
CO line
cords, 25pair
amphenol
connector,
etc.) to
the PCBs (Figure 5-8).
5-4