INSTALLATION-STATION
APPARATUS
SECTION 100-816-206
MARCH 1993
NOTE:
1. DDSS console
cable runs must not have
the folio wing:
l
Cable splits (single or double)
l
Cable bridges
(of any length)
l
High resistance
or faulty cable splices
2.
See Section
100-816-208
for secondary
protection
information.
CAUTION!
When
installing
the DDSS
cable,
do not
run parallel
to and within
3 feet of an AC
power
line.
AC power
lines
should
be
crossed
at right
(90") angles
only. In par-
ticular,
avoid
running
station
wire pairs
near devices
that generate
electricalnoise,
such as neon or fluorescent
light fixtures.
5.12 DDSS Console
Configuration.
The follow-
ing considerations
should be made when installing
DDSS consoles:
DDSS consoles
can connect
only to Circuit 8 of
the Base Unit digital
telephone
circuit set or
Circuit 8 of the PDKU.
A maximum
of two
DDSS
consoles
can be
installed
per system
equipped
with an Expan-
sion Unit.
DDSS consoles
can operate
with an attendant
electronic
telephone,
as well as with a digital
one.
A KCDU will not support
a DDSS.
5.13 DDSS Programming
Overview
Program
03
l
Code 64 identifies
the slots that support
DDSS
consoles.
Program
28
l
Assigns
DDSS console(s)
to telephones.
Program
29
l
Assigns
button
functions
for DDSS consoles.
5.20
HDSS Console
Connections
5.21
The HDSS console must be connected
to the
data pairs of circuits 7 and 8 on a PEKU in the
Expansion
Unit (via the MDF) with standard
two-
pair twisted, jacketed
telephone
cable. To accom-
modate
the connection,
the instrument
end of the
HDSS console
cable should
be terminated
in a
modular
station connector
block @J-11).
Refer to
Wiring Diagrams,
Section 100-816-208,
for wiring/
interconnecting
details.
The overall
length of the
cable run from the Expansion
Unit (KSU) to the
HDSS console
must
not exceed
500 feet (152
meters),
if using 24 AWG cable. The HDSS con-
sole can operate
with either an electronic
or digital
telephone
(preferably
an LCD model).
CAUTION!
When installing
the HDSS console
cable,
do not run parallel
to and within
3 feet of an
AC power
line. AC power
lines should
be
crossed
at right
(90") angles
only. Avoid
running
HDSS
console
wire
pairs
near
devices
thatgenerate
electricalnoise,
such
as neon
or fluorescent
light
fixtures.
5.22
HDSS
Console
Configuration.
The
fol-
lowing
considerations
should
be made when
in-
stalling an HDSS console:
A PEKU PCB is required
in the expansion
unit
for an HDSS console.
(The DSS switch on the
PEKU must be set to DSS.)
Two PEKU ports are required
for the HDSS
console
(always
Circuits 7 and 8).
The PESU does not support the HDSS console.
A system
must be configured
with the Expan-
sion Unit to support
an HDSS cohsole.
Only one
HDSS console
can be installed
in a system.
5.23
HDSS Programming
Overview
Program
03
l
Codes 23 and 24 identify the slot that supports
a PEKU that interfaces
with the HDSS console.
Program
28
l
Assigns
HDSS console
to a telephone.
Program
29
l
Assigns individual button functionsforthe
HDSS
console.
6 DOOR PHONE/LOCK
CONTROL
UNIT
AND DOOR PHONE INSTALLATION
6.01 This section provides
installation
instructions
forthedigitaldoorphone/lockcontrolunits(DDCB).
It also includes installation
instructions
for the door
phone
(MDFB).
Each DDCB can support
as many
as three door phones
(MDFBs),
or two MDFBs and
one door lock.
6-15