Toshiba strata DK8 Installation Instructions Manual page 164

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
Program
35: LED 20 should be ON to assign
auto
attendant
ports
the
"Busy
Station
Transfer"
option.
with this option
the auto
attendant
will receive
ring backtone
when
calling stations
designated
with "Busy Sta-
tion Ringing"
(Program
35, LED 19 ON). This
allows the auto attendant
to transfer
calls to
busy stations.
Set LED 19 ON for answer
position
stations.
Program
36: Set fixed call forward
to VM/AA
port per customer
requirements.
Program
37: Set the timer for the VM/AA
ports to 22 seconds
minimum
to allow call
forward
no answer to work on VM transferred
calls.
Program
39: Set the Message
Waiting
Indi-
cation, Fixed Call Forward, Redial, and Speed
Dial Select buttons
on the digital and elec-
tronic telephones
that will be used tocommu-
nicate with the VM/AA device.
NOTE:
Message
Waiting
(Msg) and Redial
buttons
are fixed buttons
on digital telephones
and it is
not necessary
to assign them in Program
39.
Speed
Dial is initialized
as Button 20 on Digi-
tal telephones.
Programs 81
w 89: Verify that the ringing
assignments
to the VM/AA
devices
are set
per customer
requirements.
Programs 16,40,41,45
- 48 and 50 - 56:
Verify that outgoing
CO line access
is al-
lowed on VM ports to allow the VM/AA beeper
notification
feature
to operate.
7.25
Voice Mail System Installation.
Install the
voice mail messaging
system
in accordance
with
the following
steps (See Figure 7-22):
1) Ensure that the QSTU, KSTU, PSTU, or PESU
PCB is installed
in the system
per Section
100-816-204
(DK8) or Section
100-816-205
(DKI 6).
2) Connect
the voice mail messaging
system to
the selected
QSTU,
KSTU,
PSTU, or PESU
3)
4)
5)
standard
telephone
ports (refer to Wiring Dia-
grams, Section
100-816-208,
for QSTU, PSTU,
KSTU, and PESU wiring/interconnecting
de-
tails).
Program
the system
for the required
voice
mail messaging
features
(refer to Paragraphs
7.13 and 7.22).
Ensure that the DK8 QRCU
or DK16 K4RCU
is installed,
and (for DK16) verify that the CTU
code in Program
03 is for KRCU-4
operation
as required (this is not required for DK8 QRCU).
Perform additional
voice mail messaging
sys-
tem programming
as applicable
(refer to cus-
tomer-supplied
installation/programming
manuals).
NOTE:
Some
voice mail devices
may ring trip when
called; in this case, set the ring voltage jumper
to L (lowposition)
on the QSTU, KSTU, PEW,
or PSTUZ PCB connected
to the voice mail
device.
8 DK16 ALARM SENSOR INSTALLATION
8.00 The PIOU or PIOUS PCB provides
a circuit
that can be set to detect
a relay open or closed
condition
from a facility alarm
system.
When the
sensor
is activated,
all electronic
and digital tele-
phones
will sound an alarm signal. The electronic/
digital telephone
alarm signal can be reset by any
electronic
or digital telephone
with an alarm reset
button
(see Program
39).
8.01 Alarm Sensor Options.
Jumper
plug P12 on
the PIOU is used to set the alarm sensor to detect
an open or closed condition
from the facility alarm
system.
Set P12 as follows
(refer to Figure 7-23):
l
To detect a closed condition,
set P12 to the N.O.
position.
l
To detect an open condition,
set P12 to the N.C.
position.