PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM
RECORDS
SECTION 100-816-302
MARCH 1993
PROGRAM 81
(I- 9)
CO LINE/STATION RINGING ASSIGNMENTS
assigned
to ring selected port
SELECT=1
-9
-
for type of ringing
number(s)
SELECT
= Logical
Port Number(s)
of station(s)
that must ring
Selected CO lines ring selected station ports per Ringing Program options as follows:
80
Immediate
Immediate
80
Immediate
I DAY
80
12 second delay
-1
8B
80
12 second delay
wl
8B 12 second delay
80
24 second delay
8m 24 second delay
8m 24 second delay
NOTE: Shaded
areas apply to DK16 only
Loaical
Port Numbers
I
CO LED
00~01~02~03~04~05~06~07~08~09/10/11~12/13~14/15~16~17~18~19
n8
m?
I
I
I
I
I
I
!
j
I
NOTES:
1. For more information,
see the instructions
preceding
the record sheets.
2.
initialized
data reads all LEDs ON for Port 00 in Program
81 and Port 01 in Program
87, all other LEDs are OFF.
3.
If a CO line must Call Forward
or Hunt from a station, the line must be assigned
to ring at that station only.
4. A range of ports may be selected.