PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECOROS
SECTION lOO-816-302
MARCH1993
LCRCOLINEPROGRAMING
1) Use Program
16 to assign CO lines in groups per the reference chart below.
CO Line Group Reference
Chart
NOTE: Shaded
areas apply to DK16 only
I
Line Group
I
CO Lines in
Group (1 - 8)
CO Line Type/Comments
I
2 (82)
I
I
3 (63)
I
4 (64)
I
5 (85)
6 (86)
7 (67)
r
8 (88)
2) Use Program
40 to allow CO lines access to stations using LCR for outgoing calls.
3) Use Program
41 to deny outgoing CO line access except for LCR access.
Important:
Area code and office code structure must be defined by Program
45-7
(Toll Restriction Dial Plan) for LCR to work properly.
4) Use Program
45-1 to enable the dial plan that is appropriate
for the area where LCR calls will originate.
PROGRAM50-1
LCRPARAMETERS
Press Button/LEDs
for each LCR parameter.
LED
X
LED On
LED Off
1
Enable System LCR
No LCR
2
Not Used
Not Used
3
555 LDI Route Per Program 50-4
Per Area Code Table
4
Dial Tone After LCR Access
Silent
5
Warning Tone Last Choice Route No.
No Warning Tone
NOTES:
1. For more information,
see the instructions preceding
the record sheets.
2. Program
40 denies CO line access via LCR and denies all other access methods.
3. Program
41 allows CO line access via LCR but denies all other outgoing access methods:
(CO line number 701 - 708, Pooled group 81 - 88, Line or Pooled Line Grp buttons).
4. Initialized data: All LEDs OFF.
5. To prevent Toll Restriction from being defeated because of K4RCU or QRCU time-out, Toll Restrictedstandard
telephones
should be forced to dial outgoing
calls via LCR.