Toshiba strata DK8 Installation Instructions Manual page 99

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-OK 16 KSU & PCB
SECTION
100-816-205
MARCH 1993
TABLE 5-F
PIOU CONTROLS AND INTERFACE CONNECTORS
CONTROL/INDICATOR/
CONNECTOR
(Figure 5-18)
SMDRTTY
interface
Connector
J3
TYPE OF COMPONENT
Dual modular
connector
DESCRIPTION
Interface
connector
for SMDR
printer/
call accounting
device and
maintenance
terminal/modem.
IMDU Connector
PI
1 O-pin connector
Interface
connector
for Remote
Maintenance
Modem
piggy-back
module.
I
IMDU Connector
P2
g-pin connector
Interface
connector
for Remote
Maintenance
Modem
piggy-back
module.
I
IMDU Connector
P3
3-pin connector
Interface
connector
for Remote
Maintenance
Modem
piggy-back
module.
I
M/B Make/Break
Three-terminal
jumper
plug
External
Page/Door
Lock Control
Relay
Jumper
Plug PlO
MAKE or BREAK jumper
plug.
I
M/B Make/Break
Three-terminal
jumper
plug
Night/Hold
Relay MAKE or BREAK
Jumper
Plug Pll
jumper
plug.
I
Alarm Sensor
N.O./N.C.
Three-terminal
jumper
plug
Alarm sensor
normally
open or normally
Jumper
Plug P12
closed jumper
plug.
I
CCIlT/BELL
Jumper
Three-terminal
jumper
plug
IMDU or external
modem
operating
Plug P13
specification
jumper
plug.
I
SMDR
Baud Rate
Two-position
slide switch
Selects baud rate (300 or 1200 bps) for
Switch SW1
SMDR printer or call accounting
device.
TTY Baud Rate Switch
SW2
Two-position
locking push-
button switch
Selects baud rate (300 or 1200 bps) for
Remote
Maintenance
Modem
piggy-back
module
(IMDU)
or external
TTY jack.
Modem/TTY
Switch
SW3
Two-position
slide switch
Enables
PIOU for operation
with IMDU
modem
or TTY jack.
2) Set the SW2 baud rateswitch
on the front panel
to 300 or 1200, as appropriate,
after the PIOU/
PIOUS
has been installed
in the Expansion
Unit (in-300 bps-out-1200
bps).
3) Set SW3 to MODEM position for IMDU operation.
4) Set the
PI3
jumper
plug on the PIOU to the
BELL position;
or, cut the W4 jumper
on the
PIOUS for BELL operation.
5) Mate IMDU
connectors
Jl, 52,
and J3 with
PIOU or PIOUS
connectors
PI, P2,
and P3
(refer to Figure 5-20).
NOTE:
PlOU of PIOUS connectors
Pl, P2, and P3
arepositioned
to allow installation
of the IMDU
only in the proper position.
6) Apply firm, even pressure
to IMDU to ensure
proper
mating
of connectors.
NOTE:
The IMDU default station intercom
number
is
619;ancilMDUcommunicationparametetsare
7-
bits, even patity, 1 -stop bit
7) Refer to Programming
Procedures,
Section
100-816-300, Program 77-1,
and set LED 14
to ON to enable
IMDU operation.
5-29