Toshiba strata DK8 Installation Instructions Manual page 32

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-CONFIGURATION
SECTION 100-816-203
MARCH 1993
l
3 CO line circuits for the three CO lines
l
7 digital telephone
circuits
l
one for each of the five digital telephones;
the PDIU-Dls
do not require
dedicated
cir-
cuits.
l
one for a digital door phone/lock
control unit
to support
a door phone
l
one for the PDIU-DS
connected
to the mo-
dem
l
2 standard
telephone
circuits
l
one for the modem
l
one for the facsimilie
machine
l
A music
source
for Music-on-hold
and Back-
ground
music
can be connected
to the Key
Service
Unit MOH RCA jacks.
5.23 Conclusion.
Several optional
PCBs in addi-
tion to the Key Service unit would be needed for the
application.
Two CO line circuits and four digital
telephone
circuits would be provided
by the KSU.
The third CO line circuit,
as well as two digital
telephone
circuits
would
be provided
by an op-
tional QCDU.
A second
QCDU
would
be neces-
sary to provide
the seventh
digital telephone
cir-
cuit. An optional
QSTU
would
provide
the two
standard
telephone
circuits.
An optional
QRCU
would be needed for the Dual-tone
Multi-frequency
(DTMF)
tones generated
by the devices
(modem
and facsimilie
machine)
connected
to the standard
telephone
lines.
5.30 The following
provides
an examples
of how to
configure
a STRATA
DKl6.
5.40 Strata DK16 - Example 1 (Bank)
5.41 Customer Requirements.
A bank needs two
CO lines and six digital telephones
(three of which
must be equipped
with a PDIU-DI).
It also wants to
connect
a printer to a PDIU-DS.
5.42 Analysis.
The banks
system
hardware
re-
quirements
are as follows:
l
Two CO line circuits for the two CO lines.
l
Seven
digital
telephone
circuits.
Six for tele-
phones
and
one
for
the
PDIU-DS.
(The
PDIU-Dls
do not require a dedicated
circuit.)
5.43 Conclusion.
A standard
Base Key Service
Unit would
be adequate
in this case. The unit's
standard
eight digital telephone
circuits and four
CO line circuits
could
easily
accommodate
the
bank's needs.
5.50 Strata DK16 - Example 2 (Office/Ware-
house)
5.51 Customer Requirements.
In addition
to five
CO lines, a small office-warehouse
facility needs
11 digital
telephones
(three
of which
will have
PDIU-Dls),
two PDIU-DSs,
a modem,
a facsimile
machine,
conference
capability,
a door
phone,
one standard
telephone,
Music-on-hold,
and an
amplifier/speaker
for paging.
5.52 Analysis.
The customer's
requirements
could
be broken
down as follows:
14 digital telephone
circuits
l
one for each of the 11 digital telephones;
the
PDIU-Dls
do not require dedicated
circuits.
l
one for each of the two PDIU-DSs
l
one for a digital door phone/lock
control unit
to support
a door phone
3 standard
telephone
circuits
l
one for the modem
l
one for the facsimile
machine
l
one for the standard
telephone
A music source for Music-on-hold
and an ampli-
fier/speaker
for paging could both be connected
to the Key Service
Unit RCA jacks.
A K4RCU
would
be needed
for the Dual-tone
Multi-frequency
(DTMF) tones generated
bythe
devices
connected
to the standard
telephone
circuits.
A PCOU would be needed
for the fifth CO line.
5.53 Conclusion.
An Expansion
Key Service Unit
in addition
to the Base Key Service Unit would be
needed
for this application.
The three standard
telephone
circuits could be contained
on the op-
tional
KSTU PCB in the Base Unit. However,
a
PDKU
installed
in the Expansion
Unit would
be
required
for six of the 14 digital telephone
circuits.
The Expansion
Unit would also be needed
for the
PCOU. The optional
K4RCU,
along with the music
source
and the page/amplifier,
as noted
earlier,
could be connected
to the Base Unit.
6 CONFIGURATION
WORKSHEETS
6.00 Worksheets
are provided
in this chapter
to
help configure
the system.
3-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk16

Table of Contents