Toshiba strata DK8 Installation Instructions Manual page 209

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-WIRING
DIAGRAMS
SECTION lOO-816-208
MARCH1993
TOPDKUIKCDUIBASE
UNIT
W/FEMALE
CONNECTOR
BR"
CIRCUIT
2 TO DKTZ
CIRCUIT
3 TO DKT3
CIRCUIT
4 TO DKT4
B
L
Y
CIRCUIT
5 TO DKT5
TERMINAL,
ETC.
CIRCUIT
6 TO DKT6
z
/, BK-0
I 37
PR &DD.
POWER1
-
---
TELEPHONE
(DKT 1)
(WITH
OR WITHOUT
PDIU-DIIPDIU-Dl2)
CIRCUIT
8 TO DKT8
. .IACKFTFll
TWISTFD
PAIRS
66M150 SPLIT BLOCK
NOTES:
1.
Voltage
levels:
T PJ = -26.3 - 27.8 VDC
' NOT USED
RJll
PR
T
R
PT
(/o-I-:-
~~~~EcTloN
,oo~o,6~207
PDIU-DS
!=i, PR = 0.0 VDC (GND)
(Reference
to SG ground)
2.
T/R wires are always
required;
PJ/PR
are additional
power
wires required
only for long station
runs or when operating
on
reserve
power
per Jab/e 8-D. PT/PR
may be used with normal
station
runs also.
RS-232
cable length
is max 50 ft with 24 A WG wire.
3
D/Us can be connected
to circuits
1 - 7 with PDKUl;
a// Base Unit, KCDU,
and PDKUZ
digital circuits
support
D/Us.
4.
Expansion
Unit slots 04 and 05 only can support
D/U.
5.
KCDU
provides
circuits
1 - 4 only.
FIGURE 8-11
OK16 MDF WIRING FOR DIGITAL TELEPHONES (DKTS) WITH PDIU-DI/PDIU-DIP AND PDIU-OS TO
PDKU, KCDU, OR BASE UNIT
8-15