Toshiba strata DK8 Installation Instructions Manual page 220

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-WIRING DIAGRAMS
SECTION 100-816-208
MARCH1993
TO
CO LINE CABLING
NETWORK
BRIDGING
KCDU
66M150
SPLIT BLOCK
NETWORK
JACK:
RJ14C
FIC: 02LS2
PIN-OUT
MODULAR
TO KCDU
J
JACKETED
TWISTED
PAIRS
Tl (VOICE/DATA)
L'IHWU
( I
-' -I*'-
'I OR 2 PAIR, SEE NOTE 2)
I
I
\
STATION
CABLING
CIRCUIT
2 TO DKT2
CIRCUIT
3 TO DKT3
CIRCUIT
4 TO DKT4
ON BOTTOM
OF PDIU-DI
PR (5)
T (4)
R (3)
PT (2)
NOTES:
66M150
SPLIT BLOCK
7. Voltage
levels:
PDIU-DI/PDIU-D12)
OR
T, PT = -26.3
- 27.8 VDC
R, PR = 0.0 VDC (GND)
- or -
(Reference
to SG ground)
DDCB
2. T/R wires are always
required;
PT/PR
are additional
power
wires required
on/y for long station
runs or when operating
on reserve
power
per Table 8-D. PT/PR
may be used with normal
station
runs also.
3. ADMs
and/or
DlUs
can be connected
to circuits
1 - 4, DDCB
can be connected
to Circuit
1.
FIGURE 8-22
DK16 MDF WIRING/CD LINES AND DIGITAL TELEPHONES TO KCDU
8-26