Toshiba strata DK8 Installation Instructions Manual page 145

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

2. Installan
HHEU PCBand
HESC-65A
cable
in the telephone
per Section
100-816-206
before proceeding
with Step 3.
3)
4
5)
6)
7)
Connect
Terminal
1 of the HESB TBl terminal
block to the red (+) wire of the HESC-65A
using a modular
block.
Connect
Terminal
2 of the HESBTBI
terminal
block to the green (-) wire of the HESC-65A
using a modular
block.
ConnectTerminal
8ofthe
HESBTBI
terminal
block to the yellow (L2) wire of the HESC65A
cable using a modular
block.
Connect
the HACU-120
power supply's +12V
lead to Terminal
1 of the HESB TB2 terminal
block, and connect the power supply's OV lead
to Terminal
2.
Plug the provided
power cord into the power
supply and to a 117VAC,
60Hz power source.
DK16
HESB
Installation
for
Electronic
Tele-
phone
Loud
Ring Bell (Figure
7-11):
1) On the HESB TBI terminal
block: connect
a
jumper
between
Terminals
6 and 7, and con-
nect anotherjumper
between
Terminals
5 and
8.
2) On the HESB TB2 terminal
block, connect
a
jumper
between
Terminals
4 and 5.
NOTES:
1. HESB
connections
made
in steps
3-6
may be accomplished
using
the HESB
VOICE modular
jack instead
of the TBI
terminal
block.
2. Install an HHEU
PCB and HESC-65
(or
HESC-65A)
cable
in the telephone
per
Section
100-816-206
before
proceeding
with Step 3.
3) Connect
Terminal
1 of the HESBTBI
terminal
block to the red (+) wire of the HESC-65
cable
using a modular
block.
4)
5)
6)
7)
8)
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
Connect
Terminal
2 of the HESB TBI terminal
block to the green
(-) wire of the HESC-65
cable using a modular
block.
Connect
Terminal
3 of the HESB TBl terminal
block to pin 3 of the electronic
telephone's
modular
block (VOICE TIP).
Connect
Terminal
4 of the HESB TBI terminal
block to Pin 4 of the electronic
telephone's
modular
block (VOICE
RING).
Connect
the HACU-120
power supply's +I 2V
lead to Terminal
1 of the HESB TB2 terminal
block, and connect the power supply's OV lead
to Terminal
2.
Plug the provided
power cord into the power
supply and to a 117VAC,
60Hz power source.
4.22 Loud
Ringing
Bell Test. Test the Loud Ring-
ing Bell installation
in accordance
with the following
steps:
1) Make a CO or station call to the station config-
ured for the loud ringing bell.
l
Ringing
will be heard over the HESB.
2) Adjust the HESB volume control to the desired
level.
(Screwdriver
adjustment
on back
of
HESB and ring level control
of associated
telephone.)
3) If ringing is heard at the station,
but not over
the HESB, perform
the following
check while
the station is ringing:
a)
Using a suitable voltmeter,
measure
volt-
age across terminals
1 (+) and 2 (-) of the
HESB TBl terminal
block.
l
Voltage
indication
should
be 4.5 -
5.0 VDC.
NOTE:
Ringing
stops once the call is manually
an-
swered.
There shouldbe
NO voltage potential
across terminals
I and 2.
b) If voltage
is not as specified
during ring-
ing, check that the telephone
wiring con-
nections
to the HESB have been made
properly
(wires to terminals
1 and 2 of the
HESBTBl
terminal
blockmay
have been
reversed).
7-13