Failure Options - Toshiba strata DK8 Installation Instructions Manual

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

INSTALLATION-OK16
KSU & PCB
SECTION lOO-816-205
MARCH 1993
13)
14)
15)
Knock out the tab on the bottom
of the side
cover.
Plug the AC power
cable into an outlet and
then turn ON the power supply switch.
Install the side cover to the Expansion
Key
Service
Unit (Figure 5-7).
2.40 Reserve
Power/Power
Failure
Options
2.41
The STRATA
DK systems
offer two options
to protect system operation
in the event of a power
failure; the Reserve Power option (Paragraph
2.42-
2.44), and the Power Failure Emergency
Transfer
option
(Paragraph
17).
2.42
Reserve
Power
Option
STRATA
DK16
system
power
supply
provides
the capability
of
connecting
a reserve power source (two customer
supplied
12-volt batteries)
to ensure uninterrupted
system operation
in the event of a power failure. A
pre-assembled
interface
cable for installation
of
the Reserve Power option is available from Toshiba
(PBTC-3M),
refer to Figure 5-9.
IMPORTANT
NOTE!
Local ordinances
may dictate
battery
type
and installation
details.
2.43 The batteries
require
a well-ventilated
loca-
tion close
(within
9 feet)
to the
system
-the
interface
cable is 9 feet long.
WARNING!
To reduce
the
risk
of fire
or injury
to
persons,
read
and
follow
these
instruc-
tions:
1.
2.
3.
Use only
the following
type
and size
batteries:
12-volt,
gelcell.
Do not dispose
of the batteries
in a fire.
The cells
may
explode.
Check
with
local
codes
for possible
special
dis-
posal
instructions.
Do not open
or mutilate
the batteries.
Released
electrolyte
is corrosive
and
may cause damage
to the eyes or skin.
It may be toxic if swallowed.
4. Exercise
care in handling
batteries
in
order not to short
the battery
with con-
duction
materials
such
as rings,
bracelets,
and
keys.
The battery
or
conductor
may
overheat
and
cause
burns.
5. Charge
the batteries
provided
with or
identified
for
use
with
this product
only
in accordance
with
the instruc-
tions
and limitations
specified
in this
manual.
6. Observe
proper
polarity
orientation
between
the
batteries
and
battery
charger.
2.44
Reserve
Power
Installation.
Install the Re-
serve Power option in accordance
with the follow-
ing steps (refer to Figure 5-9):
1) Connect the PBTCSM
black jumper wire from
the positive terminal
of one 12VDC battery to
the negative
terminal
of the second
12VDC
battery.
2) Ensure that a serviceable
1 O-ampere
fuse is
installed in the in-line fuse
holder of the PBTC-
3M battery cable.
3) Connect
the white
lead
of the PBTCSM
battery cable to the open positive terminal
of
the 12VDC battery.
Connect
the black lead to
the open
negative
terminal
of the second
12VDC
battery.
IMPORTANT
NOTE!
The KSU must
be connected
to the live
operating
(HOT)
AC power
source,
and
the power
supply
ON/OFF
switch
set to
ON prior to the final step of connecting
the
reserve
power
batteries
to the power
sup-
ply
via the
BATT
+/- receptacle.
If the
batteries
are connected
affer ACpower
is
lost, reserve
power
will not function.
4)
5)
Connect
the PBTC-3M
battery
cable
two-
prong male plug to the power supply BATT +/
- receptacle.
To test reserve
power operation,
disconnect
the system
AC power
plug with the power
supply power
ON/OFF
switch
in the ON po-
sition. The system should continue
to operate
without
any interruption.