Solid State Logic AWS DELTA 916 Owner's Manual page 195

Table of Contents

Advertisement

Mix Review
At any time you can rewind the system, and as soon as the DAW is located to an earlier time and valid MTC or a MMC
locate position command is received, the mix system enters 'Mix Review'. All faders will switch to Replay status (all LEDs
are off). This operation is known as a rollback.
When the DAW returns to Play, previously written automation data is replayed. If no faders are returned to write, all
faders in write at the start of the mix will drop back into write at the point where the DAW was rewound (the 'rollback
point', and the Mix status will return to Mix Running. Whilst in Mix Review you may rollback as many times as required
to allow the mix to be built up fader by fader. Each time a rollback takes place, the rollback counter in the mix status
display increments. Faders in write at a rollback point will automatically switch to write when the system plays through
the rollback point.
AWS elta Operator's Manual
Automation
Indicates how many times
you have rolled back. Every
time the Mix Review
number will increase by 1.
Mix Running Status
Displayed while writing
new automation data;
Mix Review Status
Displayed when rolled back
and playing previous
automation data.
Page 7-21