Solid State Logic AWS DELTA 916 Owner's Manual page 203

Table of Contents

Advertisement

A
S
UTOMATION
The SSL>MISC>SETUP contains various options for the mix system. Scroll to the option to be edited and select using
the Left V-pot push switch. Once the option is active, the left V-pot will increment/decrement a numerical value as it is
turned or page through the various option states. Press the V-pot push switch a second time to complete the setup
operation.
Glide Frames
Rollback Threshold frames
Latched Match & Play
In Mix Show
AWS elta Operator's Manual
O
ETUP
PTIONS
Sets the ramp time in frames for Snap mode. The range is from 0 (no glide) to 255
(10 second glide).
Sets the number of consecutive descending frames that the system needs to see to
determine if a rollback has taken place. The range is 2-10 and the default is 2 frames.
Increase as required if a rollback occurs on stopping the timecode master.
Normally Match and Play are automatically deselected after a Cut switch is
operated. This option latches the Match or Play function until deselected manually.
This determines what is displayed on the channels scribble strips when using
automation. Choices are:
Automation Mode - shows Manual, Safe or Auto
Channel names in mix running - After pressing Execute will
display channel names
Channel names - will always display channel names
Automation
Page 7-29