Siemens SIPROTEC 7SA6 Manual page 530

Distance protection relay for all voltage levels
Hide thumbs Also See for SIPROTEC 7SA6:
Table of Contents

Advertisement

Control During Operation
Table 7-1
Operational measured values
Measured values
I
, I
, I
L1
L2
L3
3I
0
I
, I
1
2
3I0
sen
I
, I
Y
P
U
, U
, U
L1–L2
L2–L3
L3–L1
U
, U
, U
L1–E
L2–E
L3–E
3U
0
U
X
U
, U
1
2
R
, R
, R
L1–E
L2–E
L3–E
R
, R
, R
L1–L2
L1–L2
L3–L1
X
, X
, X
L1–E
L2–E
L3–E
X
, X
, X
L1–L2
L2–L3
L3–L1
S, P, Q
ϕ
cos
f
Θ
, Θ
,
L1
trip
L2
trip
Θ
L3
trip
Θ/Θ
trip
U
, U
, U
line
sync
diff
f
, f
, f
line
sync
diff
ϕ
diff
3I0senA, 3I0senR
1
) acc. to address 1104 (refer to Sub-section 6.1.3)
3
) with consideration of the factor 221 I4/Iph CT (refer to Sub-section 6.1.1)
4
) with consideration of the factor 211 Uph / Udelta (refer to Sub-section 6.1.1)
7-16
If the device is provided with earth fault detection in a non-earthed system, also the
components of the earth fault current (active and reactive components) are indicated.
In addition to those measured values listed in the table, it is possible to retrieve user
defined measurement, metering and set points, if these were generated during the
configuration of the device according to Section 5.2 and/or 5.3 "Generating user de-
finable functions with CFC".
phase currents
earth currents
pos. and neg. seq. currents
sensitive earth current
transformer star point current or
earth current in the parallel line
line voltages
phase-earth voltages
displacement voltage
voltage at the measuring input U
pos. and neg. seq. voltages
operational resistance of all phase
loops
operational reactance of all phase
loops
apparent, real, and reactive power MVA, MW,
power factor
frequency
thermal value of each phase
related to trip value
thermal value,
related to trip value, calculated
according to the configured method
line voltage, busbar voltage and
voltage magnitude difference
(for synchronism check)
line voltage, busbar voltage and
frequency difference
(for synchronism check)
magnitude of the phase angle dif-
ference between line and busbar
(for sychronism check)
active and reactive components of
earth fault current
primary
secondary
A
A
A
A
A
A
A
mA
A
A
kV
V
kV
V
kV
V
kV
V
4
kV
V
MVAR
(abs)
(abs)
Hz
Hz
kV
Hz
°
A
mA
2
) acc. to address1103 (refer to Sub-section 6.1.3)
% referred to
rated operational current
rated operational current
rated operational current
rated operational current
rated operational current
rated operational voltage
rated operational voltage
rated operational voltage
rated operational voltage
rated operational voltage
√ 3·U
·I
N
N
rated operational values
rated frequency
temperature rise
temperature rise
7SA6 Manual
C53000-G1176-C156-2
1
)
1
)
1
)
1
3
)
)
1
3
)
)
2
)
/ √ 3
2
)
· √ 3
2
4
)
)
/ √ 3
2
)
/ √ 3
2
)
1
2
)
)

Advertisement

Table of Contents
loading

Table of Contents