U244

Chk DP Switch

Description
Displays the status of the respective switches in the DP.
Purpose
To check if respective switches in the DP operate correctly.
Method
1. Press the start key.
2. Turn each switch or sensor on and off manually to check the status.
Display
Switch
* : State of the switches are updated regularly.
* : State of the switches are represented by 0:OFF and 1:ON.
* : 7-digit numeric representation, each digit corresponds to the state of the switch.
7th digit
cover_ open
Example: longitudinal switch is ON
set switch is ON
feed and timing switches are ON : 0010100
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
State of the switch
6th digit
5th digit
open
feed
Description
4th digit
3th digit
regist
timing
: 0000001
: 0000010
1-3-61
2NC/2NF/2NG/2NN/3P7/3P8/3P9
2th digit
1th digit
set
longitudinal