(3) Periodic maintenance procedures

Check the maintenance counts by the maintenance mode U901.
(3-1) Main unit
CH: Check, CL: Clean, AD: Adjust, LU: Lubrication, RE: Replace
Maintenance
Section
part/location
Test copy
Image Quality
and test
print
Maintenance
Section
part/location
PF sec-
Primary paper feed
tion
unit
Retard roller
Pickup roller
MP paper feed roller
Retard guide
Right registration
roller
Registration roller
cleaner
Left registration
roller
Periodic
maintenance
User
(x1000 counts)
call
150
CH
CH
AD
AD
Periodic
maintenance
User
(x1000 counts)
call
150
CH
RE
CH
RE
CH
RE
CH
CL
RE
CH
RE
CH
CL
RE
CH
CL
RE
CH
CL
CL
2-3-4
2NC/2NF/2NG/2NN/3P7/3P8/3P9-3
Points and cautions
Perform at the maximum copy size
Points and cautions
CH: Clean with alcohol if it is dirty.
Replace if there are any prob
lems such as damage or friction.
CH: Clean with alcohol if it is dirty.
Replace if there are any prob-
lems such as damage or friction.
CH: Clean with alcohol if it is dirty.
Replace if there are any prob-
lems such as damage or friction.
CL: Alcohol
CH: Clean with alcohol if it is dirty.
Replace if there are any prob-
lems such as damage or friction.
CH: Clean with alcohol if it is dirty.
Replace if there are any prob-
lems such as damage or friction.
CL: Alcohol
CH: Clean with alcohol if it is dirty.
Replace if there are any prob-
lems such as damage or friction.
CL: Absorb the paper dust using
vacuum
CH: Replace if the pad is damaged
or scrapped.
CL: Alcohol or dry cloth
CH: Clean with alcohole if it is dirty.
Page
-
Page
P.1-5-5
P.1-5-8
P.1-5-5
P.1-5-14
P.1-5-12
P.1-5-42
P.1-5-10
P.1-5-42