Controlling The R&S Osp-B131; Controlling The R&S Osp-B116/-B136 - R&S OSP Operating Manual

Open switch and control unit
Table of Contents

Advertisement

R&S OSP
3.3.11 Controlling the R&S OSP-B131
After selection of the R&S OSP-B131 module the following dialog is opened.
The module R&S OSP-B131 contains two SPDT relays.
Clicking to the symbol of the relay, the position of each relay can be toggled
individually.
SPDT switch
Note that the terminal NC assigns the Normally Closed position. When the relay is not
activated, terminal NC is connected to terminal C.
The terminal NO is the Normally Open position. If the relay is activated, the terminal
NO is connected to terminal C.
The buttons K11 and K12 are not required for manual operation of the switches, but
for defining a path configuration (see
K12
Any button K11 and/or K12 in grey color indicates that this relay is not selected. A non
selected relay is not considered when defining a path configuration.
K11
To take over particular relays into the path configuration, the relay buttons must be
selected by clicking on each of the relay buttons required. The selected relay is
displayed with a button in green color. All relays whose relay buttons are selected are
taken over into a path configuration.
Pressing the Shift key while clicking on a relay button will toggle between selecting all
relays of this module and deselecting all of them.
OSP-B131 dialog
When the dialog for operation of the R&S OSP-B131 module is opened, the actual
relay setting of this module is read back from the hardware and displayed.
3.3.12 Controlling the R&S OSP-B116/-B136
After selection of the R&S OSP-B116 and OSP-B136 module, respectively, one of the
following dialogs is opened.
Operating Manual 1505.3896.12 - 14