READ:RELay:OPERations? <channel_list>
Acquires the number of operation cycles of each relay (and even of I/O channels) that
appears in the <channel_list>. The instrument returns a number for each relay or
channel in the list, in the same order as the list is specified. For example a response of
100 means the relay has been closed a hundred times and opened again in it's life
time. The number of operation cycles of each relay is stored durable in the flash
EEPROM of the module the relay is part of. This is done after every hour of operation
time of an R&S OSP (only if the counter has changed). This is also done when the
instrument receives the query command READ:RELay:OPERations? To make sure
that no operation cycles 'get lost' this READ query command should be sent before a
remote control session is quit.
'<channel_list>'
Example
Characteristics
READ:MODule:INTerlock? <module_name>
Acquires the interlock state of a relay module. At the moment this command applies
only to module R&S OSP-B104 and is ignored if <module_name> specifies any other
module. For more information about the meaning of interlock, please refer to the
description of module R&S OSP-B104.
'<module_name>'
Example
Characteristics
Operating Manual 1505.3896.12 - 14
List of relays and I/O channels and their condition the number of
operation cycles is queried.
For more information on naming conventions and how a channel
list is built up, please refer to
READ:RELay:OPERations? (@F01A11(0101,0105))
Response: 86,1267
Relay 1 on module at position A11 in R&S OSP instrument with
ID F01 was set 86 times to condition 1 in it's life time.
Relay 5 on module at position A11 in R&S OSP instrument with
ID F01 was set 1267 times to condition 1 in it's life time.
Firmware version V1.1
Device-specific. Query only.
Represents the ID of an R&S OSP-B104 module within an
R&S OSP instrument.
For more information on naming conventions and how a module
ID is built up, please refer to
READ:MODule:INTerlock? F01A12
Response: 1
The R&S OSP-B104 module at position A12 in R&S OSP
instrument with ID F01 is in interlock state.
Firmware version V1.1
Device-specific. Query only.
Remote Command Reference
chapter
7.2, Naming Conventions.
chapter
7.2, Naming Conventions.
159