R&S Osp Module Interfaces; R&S Osp-B101/-B107/-B111/-B127 Interface - R&S OSP Operating Manual

Open switch and control unit
Table of Contents

Advertisement

R&S OSP
Command
&POL
&NREN
9.2 R&S OSP Module Interfaces
The following chapters describes the interface of the available R&S OSP modules and
particular precautions for connection, if required.
9.2.1 R&S OSP-B101/-B107/-B111/-B127 Interface
The module R&S OSP-B101 and others as listed above are single slot modules. They
contain 6 SPDT relays which are directly accessible at the module's front panel. There
are no additional RF cables inside the module.
Here is a picture of the R&S OSP-B101:
The following drawing shows the pinout. All RF connectors are SMA female type.
NO
C
NC
K11
Figure 9-5: Layout RF Connectors of R&S OSP-B101
SMA Connectors
It is urgently recommended to use an SMA torque wrench (60 Ncm) to screw on and
unscrew the RF connectors from the R&S OSP-B101 module.
The module description as given above applies to further options of the R&S OSP as
far as the option has got a similar relay configuration. It will apply to the following
modules:
Operating Manual 1505.3896.12 - 14
Effect on the instrument
(Serial Poll)
Starts a serial poll.
(Not Remote
Enables switchover from remote control to manual control by means of the
Enable)
front panel keys.
NO
NO
NO
NO
C
C
C
C
NC
NC
NC
NC
K12
K13
K14
K15
NO
C
NC
K16
Appendix