2.3.4 Electric Wiring Work and Initial Setting
1. Electric Wiring Work
X1A
AC200V
~240V
RED
L
INPUT
Aiarm
Monitor
N
(RED)
H1P
Operation
X1M
Monitor
(GRN)
H9P
LED10
HAP
RED
TP1
HAP
GRN
TNa1
TNb1
TNa2
TNb2
TNa3
TNb3
TNa4
TNc1
TNc2
TNc3
X4M
CD
D1
D2
D3
1
2. Initial setting
DEC102A51 Switch Settings
SS1
Output switching
DS2
Abnormal input detection Open/Close
DS3
Buzzer output ON/OFF
DS4-1
Instantaneous automatic recovery
DS4-2
Transmission failure
DS4-3
Last command priority
DS4-4
Start/stop failure
DS5
Abnormal output shutoff/retain
DS6-1
Startup failure
DS6-2
Failure detection
DS6-3
Monitor input
DS6-4
Forced termination
Note:
1. All are set to "OFF" upon shipment from factory.
2. *1 If operating feedback input is not detected within 10 seconds after 1 operation input is received, it results in start/
stop failure.
2.3 Dio Unit <DEC102A51>
No simultaneous clamping is allowed for high-voltage wiring
<power supply wiring (L/N), earth wiring, relay output wiring
(CD, D1 to 4)>, low-voltage wiring <communication wiring (F1/F2),
operation input wiring (CM, M1 to 4) and abnormal input wiring
X2M
X2A
(CA, A1 to 4)> since malfunctioning may result.
F1
YE
F2
1
2
3
4
Also, in case where the wirings described above are routed in parallel,
Group No. Set
H10P
DS1 High
RS1 Low
0
H2P
H3P
H4P
be sure to connect the wirings at least 50mm apart from the other.
H10P
H11P H12P
DS3
DS2
1
2
3
4
5
6
7
8
ON
DS5
DS4
1
2
3
4
5
6
7
8
ON
DS6
ON
1
2
3
4
TNb4
Contact switch
SS1
Con.
Ins.
X3M
TNc4
CA
A1
A2
A3
A4
D4
CM
M1
M2
M3
M4
2
3
4
Name
To 1~200-240V and earth
To facility equipment
To facility equipment
To terminals F1, F2 of the centralized control equipment or terminals
F1, F2 of other equipment
(outdoor unit, DEC101A51, 102A51)
Operation
Switching control output
Failure detection
Open: Close (Normal) → Open (Abnormal)
Close: Open (Normal) → Close (Abnormal)
ON/OFF switching of buzzer output of
buzzer unit upon detection of failure.
Recover control output after power failure
to status before the power failure.
Shut off control output upon detecting
transfer failure.
Allowing start/stop control from facility.
Detecting start/stop failure. (*1)
Shut off control output upon detecting
failure.
Masking time after detecting operation
input.
Operation upon recovery from failure.
Detecting failure under halting status.
Ignoring forced stop signal.
Adaptor
OFF
ON
Always output
Always output
"1"
"2"
Open
Close
ON
OFF
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
10 seconds
30 seconds
Automatic
Retained
reset
Yes
No
No
Yes
129
4