Siemens SIPROTEC 7SD610 Manual page 407

Hide thumbs Also See for SIPROTEC 7SD610:
Table of Contents

Advertisement

No.
Description
2821
AR dead time after evolving fault
(AR Td. evol.Flt)
2839
AR dead time after 1pole trip
running (AR Tdead 1pTrip)
2840
AR dead time after 3pole trip
running (AR Tdead 3pTrip)
2841
AR dead time after 1phase fault
running (AR Tdead 1pFlt)
2842
AR dead time after 2phase fault
running (AR Tdead 2pFlt)
2843
AR dead time after 3phase fault
running (AR Tdead 3pFlt)
2844
AR 1st cycle running (AR 1stCyc.
run.)
2845
AR 2nd cycle running (AR
2ndCyc. run.)
2846
AR 3rd cycle running (AR 3rdCyc.
run.)
2847
AR 4th or higher cycle running
(AR 4thCyc. run.)
2848
AR cycle is running in ADT mode
(AR ADT run.)
2851
AR: Close command (AR CLOSE
Cmd.)
2852
AR: Close command after 1pole,
1st cycle (AR Close1.Cyc1p)
2853
AR: Close command after 3pole,
1st cycle (AR Close1.Cyc3p)
2854
AR: Close command 2nd cycle
(and higher) (AR Close 2.Cyc)
2861
AR: Reclaim time is running (AR
T-Recl. run.)
2862
AR successful (AR successful)
2864
AR: 1pole trip permitted by inter-
nal AR (AR 1p Trip Perm)
2865
AR: Synchro-check request (AR
Sync.Request)
2871
AR: TRIP command 3pole (AR
TRIP 3pole)
2889
AR 1st cycle zone extension
release (AR 1.CycZoneRel)
2890
AR 2nd cycle zone extension
release (AR 2.CycZoneRel)
2891
AR 3rd cycle zone extension
release (AR 3.CycZoneRel)
2892
AR 4th cycle zone extension
release (AR 4.CycZoneRel)
2893
AR zone extension (general) (AR
Zone Release)
2894
AR Remote close signal send
(AR Remote Close)
2895
No. of 1st AR-cycle CLOSE com-
mands,1pole (AR #Close1./1p=)
2896
No. of 1st AR-cycle CLOSE com-
mands,3pole (AR #Close1./3p=)
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
Function
Type
of In-
for-
matio
n
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Auto Reclose
OUT
*
Statistics
VI
Statistics
VI
Log Buffers
Configurable in Matrix
on off
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
*
LED
on
m
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
on
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
on
*
LED
Appendix
A.8 Information List
IEC 60870-5-103
BO
40
197
2
Yes
BO
40
148
2
Yes
BO
40
149
2
Yes
BO
40
150
2
Yes
BO
40
151
2
Yes
BO
40
154
2
Yes
BO
40
155
2
Yes
BO
40
157
2
Yes
BO
40
158
2
Yes
BO
40
159
2
Yes
BO
40
130
2
Yes
BO
192
128
2
No
BO
40
152
1
Yes
BO
40
153
1
Yes
BO
192
129
1
No
BO
40
161
1
Yes
BO
40
162
1
Yes
BO
40
164
1
Yes
BO
40
165
2
Yes
BO
40
171
2
Yes
BO
40
160
1
Yes
BO
40
169
1
Yes
BO
40
170
1
Yes
BO
40
172
1
Yes
BO
40
173
1
Yes
BO
40
129
2
Yes
407

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents