Siemens SIPROTEC 7SD610 Manual page 391

Hide thumbs Also See for SIPROTEC 7SD610:
Table of Contents

Advertisement

Addr.
Parameter
2686
I>Dir.Telep/BI
2687
I> Dir. SOTF
2688
Direction IP
2689
Ip> Dir.
2690
T Ip Dir.
2691
D Ip Dir.
2692
T Ip Add Dir.
2693
Direction 3I0P
2694
3I0p Dir.
2695
T 3I0p Dir.
2696
D 3I0p Dir.
2697
T 3I0p Add Dir.
2698
IPDir.Telep/BI
2699
IP Dir. SOTF
2901
MEASURE. SUPERV
2902A
BALANCE U-LIMIT
2903A
BAL. FACTOR U
2904A
BALANCE I LIMIT
2905A
BAL. FACTOR I
2906A
ΣI THRESHOLD
2907A
ΣI FACTOR
2908A
T BAL. U LIMIT
2909A
T BAL. I LIMIT
2910
FUSE FAIL MON.
2911A
FFM U>(min)
2912A
FFM I< (max)
2913A
FFM U<max (3ph)
2914A
FFM Idelta (3p)
2915
V-Supervision
2916A
T V-Supervision
2921
T mcb
2931
BROKEN WIRE
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
Function
C
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
Forward
Reverse
Back-Up O/C
1A
0.10 .. 4.00 A; ∞
5A
0.50 .. 20.00 A; ∞
Back-Up O/C
0.05 .. 3.00 sec; ∞
Back-Up O/C
0.50 .. 15.00 ; ∞
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
Forward
Reverse
Back-Up O/C
1A
0.05 .. 4.00 A; ∞
5A
0.25 .. 20.00 A; ∞
Back-Up O/C
0.05 .. 3.00 sec; ∞
Back-Up O/C
0.50 .. 15.00 ; ∞
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
0.58 .. 0.95
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
0.10 .. 0.95
Measurem.Superv
1A
0.10 .. 2.00 A
5A
0.50 .. 10.00 A
Measurem.Superv
0.00 .. 0.95
Measurem.Superv
5 .. 100 sec
Measurem.Superv
5 .. 100 sec
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
2 .. 100 V
Measurem.Superv
1A
0.05 .. 1.00 A
5A
0.25 .. 5.00 A
Measurem.Superv
w/ CURR.SUP
w/ I> & CBaux
OFF
Measurem.Superv
0.00 .. 30.00 sec
Measurem.Superv
0 .. 30 ms
Measurem.Superv
ON
OFF
Alarm only
Setting Options
Default Setting
NO
NO
Forward
∞ A
∞ A
0.50 sec
5.00
0.00 sec
Forward
∞ A
∞ A
0.50 sec
5.00
0.00 sec
NO
NO
ON
50 V
0.75
0.50 A
2.50 A
0.50
0.25 A
1.25 A
0.50
5 sec
5 sec
ON
30 V
0.10 A
0.50 A
15 V
0.10 A
0.50 A
w/ CURR.SUP
3.00 sec
0 ms
OFF
Appendix
A.7 Settings
Comments
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Direction of stage Ip> Dir.
Ip> directional Pickup
T Ip Dir.: Inv.-Time delay for IEC-
Char.
D 3I0p Dir.:Inv.-Time delay for
ANSI-Ch.
T 3I0p Dir.: additional time delay
Direction of stage 3I0p
3I0p directional Pickup
T 3I0p Dir.:Inv.-Time delay for
IEC-Char
D 3I0p Dir.:Inv.-Time delay for
ANSI-Ch.
T 3I0p Dir.: additional time delay
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Measurement Supervision
Voltage Threshold for Balance
Monitoring
Balance Factor for Voltage
Monitor
Current Balance Monitor
Balance Factor for Current
Monitor
Summated Current Monitoring
Threshold
Summated Current Monitoring
Factor
T Balance Factor for Voltage
Monitor
T Current Balance Monitor
Fuse Failure Monitor
Minimum Voltage Threshold U>
Maximum Current Threshold I<
Maximum Voltage Threshold U<
(3phase)
Delta Current Threshold
(3phase)
Voltage Failure Supervision
Delay Voltage Failure Supervi-
sion
VT mcb operating time
Fast broken current-wire supervi-
sion
391