No.
Description
506
Relay PICKUP Earth (Relay
PICKUP E)
507
Relay TRIP command Phase L1
(Relay TRIP L1)
508
Relay TRIP command Phase L2
(Relay TRIP L2)
509
Relay TRIP command Phase L3
(Relay TRIP L3)
510
Relay GENERAL CLOSE
command (Relay CLOSE)
511
Relay GENERAL TRIP command
(Relay TRIP)
512
Relay TRIP command - Only
Phase L1 (Relay TRIP 1pL1)
513
Relay TRIP command - Only
Phase L2 (Relay TRIP 1pL2)
514
Relay TRIP command - Only
Phase L3 (Relay TRIP 1pL3)
515
Relay TRIP command Phases
L123 (Relay TRIP 3ph.)
530
LOCKOUT is active (LOCKOUT) P.System Data 2
533
Primary fault current IL1 (IL1 =)
534
Primary fault current IL2 (IL2 =)
535
Primary fault current IL3 (IL3 =)
536
Relay Definitive TRIP (Definitive
TRIP)
545
Time from Pickup to drop out (PU
Time)
546
Time from Pickup to TRIP (TRIP
Time)
560
Single-phase trip was coupled
3phase (Trip Coupled 3p)
561
Manual close signal detected
(Man.Clos.Detect)
562
CB CLOSE command for manual
closing (Man.Close Cmd)
563
CB alarm suppressed (CB Alarm
Supp)
590
Line closure detected (Line clo-
sure)
591
Single pole open detected in L1
(1pole open L1)
592
Single pole open detected in L2
(1pole open L2)
593
Single pole open detected in L3
(1pole open L3)
916
Increment of active energy
(WpΔ=)
917
Increment of reactive energy
(WqΔ=)
1000
Number of breaker TRIP com-
mands (# TRIPs=)
1001
Number of breaker TRIP com-
mands L1 (TripNo L1=)
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
Function
Type
of In-
for-
matio
n
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
*
IntSP
on
off
P.System Data 2
VI
*
P.System Data 2
VI
*
P.System Data 2
VI
*
P.System Data 2
OUT
on
P.System Data 2
VI
P.System Data 2
VI
P.System Data 2
OUT
*
P.System Data 2
OUT
on
P.System Data 2
OUT
*
P.System Data 2
OUT
*
P.System Data 2
OUT
on
off
P.System Data 2
OUT
on
off
P.System Data 2
OUT
on
off
P.System Data 2
OUT
on
off
Energy
-
Energy
-
Statistics
VI
Statistics
VI
Log Buffers
Configurable in Matrix
*
m
LED
*
m
LED
*
m
LED
*
m
LED
*
*
LED
off
m
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
on off
on off
on off
on
LED
on
*
LED
*
*
LED
*
*
LED
*
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
Appendix
A.8 Information List
IEC 60870-5-103
BO
192
67
2
Yes
BO
192
69
2
No
BO
192
70
2
No
BO
192
71
2
No
BO
BO
192
68
2
No
BO
BO
BO
BO
BO
150
177
4
No
150
178
4
No
150
179
4
No
BO
150
180
2
Yes
BO
150
210
2
No
BO
150
211
1
No
BO
150
212
1
No
BO
BO
BO
BO
BO
403