Siemens SIPROTEC 7SD610 Manual page 392

Hide thumbs Also See for SIPROTEC 7SD610:
Table of Contents

Advertisement

Appendix
A.7 Settings
Addr.
Parameter
2933
FAST Σ i SUPERV
2935A
ΔI min
2941
ϕA
2942
ϕB
2943
I1>
2944
U1>
3401
AUTO RECLOSE
3402
CB? 1.TRIP
3403
T-RECLAIM
3403
T-RECLAIM
3404
T-BLOCK MC
3406
EV. FLT. RECOG.
3407
EV. FLT. MODE
3408
T-Start MONITOR
3409
CB TIME OUT
3410
T RemoteClose
3411A
T-DEAD EXT.
3420
AR WITH DIFF
3421
AR w/ SOTF-O/C
3423
AR WITH I.TRIP
3424
AR w/ DTT
3425
AR w/ BackUpO/C
3430
AR TRIP 3pole
3431
DLC / RDT
3433
T-ACTION ADT
3434
T-MAX ADT
3435
ADT 1p allowed
3436
ADT CB? CLOSE
3437
ADT SynRequest
3438
T U-stable
3440
U-live>
3441
U-dead<
3450
1.AR: START
3451
1.AR: T-ACTION
3453
1.AR Tdead 1Flt
3454
1.AR Tdead 2Flt
392
Function
C
Measurem.Superv
ON
OFF
Measurem.Superv
1A
0.05 .. 1.00 A
5A
0.25 .. 5.00 A
Measurem.Superv
0 .. 359 °
Measurem.Superv
0 .. 359 °
Measurem.Superv
1A
0.05 .. 2.00 A
5A
0.25 .. 10.00 A
Measurem.Superv
2 .. 70 V
Auto Reclose
OFF
ON
Auto Reclose
YES
NO
Auto Reclose
0.50 .. 300.00 sec
Auto Reclose
0.50 .. 300.00 sec; 0
Auto Reclose
0.50 .. 300.00 sec; 0
Auto Reclose
with PICKUP
with TRIP
Auto Reclose
Stops AutoRecl
starts 3p AR
Auto Reclose
0.01 .. 300.00 sec
Auto Reclose
0.01 .. 300.00 sec
Auto Reclose
0.00 .. 300.00 sec; ∞
Auto Reclose
0.50 .. 300.00 sec; ∞
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
WITHOUT
DLC
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.50 .. 3000.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.10 .. 30.00 sec
Auto Reclose
30 .. 90 V
Auto Reclose
2 .. 70 V
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Setting Options
Default Setting
ON
0.10 A
0.50 A
200 °
340 °
0.05 A
0.25 A
20 V
ON
NO
3.00 sec
3.00 sec
1.00 sec
with TRIP
starts 3p AR
0.50 sec
3.00 sec
0.20 sec
∞ sec
YES
YES
YES
YES
YES
YES
WITHOUT
0.20 sec
5.00 sec
NO
NO
NO
0.10 sec
48 V
30 V
YES
0.20 sec
1.20 sec
1.20 sec
C53000-G1176-C145-6, Release date 02.2011
Comments
State of fast current summation
supervis
Min. current diff. for wire break
det.
Limit setting PhiA
Limit setting PhiB
Minimum value I1>
Minimum value U1>
Auto-Reclose Function
CB ready interrogation at 1st trip
Reclaim time after successful AR
cycle
Reclaim time after successful AR
cycle
AR blocking duration after
manual close
Evolving fault recognition
Evolving fault (during the dead
time)
AR start-signal monitoring time
Circuit Breaker (CB) Supervision
Time
Send delay for remote close
command
Maximum dead time extension
AR with differential protection ?
AR with switch-onto-fault over-
current ?
AR with intertrip ?
AR with direct transfer trip ?
AR with back-up overcurrent ?
3pole TRIP by AR
Dead Line Check / Reduced
Dead Time
Action time
Maximum dead time
1pole TRIP allowed
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
Supervision time for dead/live
voltage
Voltage threshold for live line or
bus
Voltage threshold for dead line or
bus
Start of AR allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
SIPROTEC, 7SD610, Manual