Siemens SIPROTEC 7SD610 Manual page 396

Hide thumbs Also See for SIPROTEC 7SD610:
Table of Contents

Advertisement

Appendix
A.7 Settings
Addr.
Parameter
3932
T-PoleDiscrep.
4001
FCT TripSuperv.
4002
No. of BI
4003
Alarm Delay
4101
REF PROT.
4111
I-REF>
4112A
T I-REF>
4113A
SLOPE
4201
Ther. OVERLOAD
4202
K-FACTOR
4203
TIME CONSTANT
4204
Θ ALARM
4205
I ALARM
4206
CALC. METHOD
4501
STATE PROT I 1
4502
CONNEC. 1 OVER
4505A
PROT 1 T-DELAY
4506A
PROT 1 UNSYM.
4509
T-DATA DISTURB
4510
T-DATAFAIL
4511
PI1 SYNCMODE
4512
Td ResetRemote
4513A
PROT1 max ERROR
4515A
PI1 BLOCK UNSYM
4701
ID OF RELAY 1
4702
ID OF RELAY 2
4710
LOCAL RELAY
4801
GPS-SYNC.
4803A
TD GPS FAILD
396
Function
C
Breaker Failure
0.00 .. 30.00 sec; ∞
TripCirc.Superv
ON
OFF
TripCirc.Superv
1 .. 2
TripCirc.Superv
1 .. 30 sec
REF
OFF
ON
REF
1A
0.05 .. 2.00 A
5A
0.25 .. 10.00 A
REF
0.00 .. 60.00 sec; ∞
REF
0.00 .. 0.95
Therm. Overload
OFF
ON
Alarm Only
Therm. Overload
0.10 .. 4.00
Therm. Overload
1.0 .. 999.9 min
Therm. Overload
50 .. 100 %
Therm. Overload
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
Therm. Overload
Θ max
Average Θ
Θ from Imax
Prot. Interface
ON
OFF
Prot. Interface
F.optic direct
Com conv 64 kB
Com conv 128 kB
Com conv 512 kB
C37.94 1 slot
C37.94 2 slots
C37.94 4 slots
C37.94 8 slots
Prot. Interface
0.1 .. 30.0 ms
Prot. Interface
0.000 .. 3.000 ms
Prot. Interface
0.05 .. 2.00 sec
Prot. Interface
0.0 .. 60.0 sec
Prot. Interface
TEL and GPS
TEL or GPS
GPS SYNC OFF
Prot. Interface
0.00 .. 300.00 sec; ∞
Prot. Interface
0.5 .. 20.0 %
Prot. Interface
YES
NO
Diff.-Topo
1 .. 65534
Diff.-Topo
1 .. 65534
Diff.-Topo
relay 1
relay 2
Prot. Interface
ON
OFF
Prot. Interface
0.5 .. 60.0 sec
Setting Options
Default Setting
2.00 sec
OFF
2
2 sec
OFF
0.15 A
0.75 A
0.00 sec
0.00
OFF
1.10
100.0 min
90 %
1.00 A
5.00 A
Θ max
ON
F.optic direct
30.0 ms
0.100 ms
0.10 sec
6.0 sec
TEL and GPS
0.00 sec
1.0 %
YES
1
2
relay 1
OFF
2.1 sec
C53000-G1176-C145-6, Release date 02.2011
Comments
Trip delay with pole discrepancy
TRIP Circuit Supervision is
Number of Binary Inputs per trip
circuit
Delay Time for alarm
Restricted Earth Fault Protection
Pick up value I REF>
T I-REF> Time Delay
Slope of Charac. I-REF> = f(I-
SUM)
Thermal overload protection
K-Factor
Time Constant
Thermal Alarm Stage
Current Overload Alarm Setpoint
Method of Acquiring Tempera-
ture
State of protection interface 1
Connection 1 over
Prot 1: Maximal permissible
delay time
Prot 1: Diff. in send and receive
time
Time delay for data disturbance
alarm
Time del for transmission failure
alarm
PI1 Synchronizationmode
Remote signal RESET DELAY
for comm.fail
Prot 1: Maximal permissible error
rate
Prot.1: Block. due to unsym.
delay time
Identification number of relay 1
Identification number of relay 2
Local relay is
GPS synchronization
Delay time for local GPS-pulse
loss
SIPROTEC, 7SD610, Manual