A.7 Settings
Addr.
Parameter
2614
I>> Telep/BI
2615
I>> SOTF
2620
Iph>
2621
T Iph>
2622
3I0>
2623
T 3I0>
2624
I> Telep/BI
2625
I> SOTF
2630
Iph> STUB
2631
T Iph STUB
2632
3I0> STUB
2633
T 3I0 STUB
2634
I-STUB Telep/BI
2635
I-STUB SOTF
2640
Ip>
2642
T Ip Time Dial
2643
Time Dial TD Ip
2646
T Ip Add
2650
3I0p PICKUP
2652
T 3I0p TimeDial
2653
TimeDial TD3I0p
2656
T 3I0p Add
2660
IEC Curve
2661
ANSI Curve
2670
I(3I0)p Tele/BI
2671
I(3I0)p SOTF
2680
Direction Iph>
2681
Iph> Dir.
2682
T Iph> Dir.
2683
Direction 3I0>
2684
3I0> Dir.
2685
T 3I0> Dir.
390
Function
C
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
1A
0.05 .. 50.00 A; ∞
5A
0.25 .. 250.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Back-Up O/C
1A
0.05 .. 25.00 A; ∞
5A
0.25 .. 125.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
1A
0.05 .. 50.00 A; ∞
5A
0.25 .. 250.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Back-Up O/C
1A
0.05 .. 25.00 A; ∞
5A
0.25 .. 125.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
1A
0.10 .. 4.00 A; ∞
5A
0.50 .. 20.00 A; ∞
Back-Up O/C
0.05 .. 3.00 sec; ∞
Back-Up O/C
0.50 .. 15.00 ; ∞
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
1A
0.05 .. 4.00 A; ∞
5A
0.25 .. 20.00 A; ∞
Back-Up O/C
0.05 .. 3.00 sec; ∞
Back-Up O/C
0.50 .. 15.00 ; ∞
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
Normal Inverse
Back-Up O/C
Very Inverse
Extremely Inv.
LongTimeInverse
Back-Up O/C
Inverse
Back-Up O/C
Short Inverse
Long Inverse
Moderately Inv.
Very Inverse
Extremely Inv.
Definite Inv.
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Back-Up O/C
Non-Directional
Forward
Reverse
Back-Up O/C
1A
0.05 .. 50.00 A; ∞
5A
0.25 .. 250.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Back-Up O/C
Non-Directional
Forward
Reverse
Back-Up O/C
1A
0.05 .. 25.00 A; ∞
5A
0.25 .. 125.00 A; ∞
Back-Up O/C
0.00 .. 30.00 sec; ∞
Setting Options
Default Setting
YES
NO
1.50 A
7.50 A
0.50 sec
0.20 A
1.00 A
2.00 sec
NO
NO
1.50 A
7.50 A
0.30 sec
0.20 A
1.00 A
2.00 sec
NO
NO
∞ A
∞ A
0.50 sec
5.00
0.00 sec
∞ A
∞ A
0.50 sec
5.00
0.00 sec
Normal Inverse
Inverse
NO
NO
Non-Directional
1.50 A
7.50 A
0.50 sec
Non-Directional
0.20 A
1.00 A
2.00 sec
C53000-G1176-C145-6, Release date 02.2011
Comments
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Iph> Pickup
T Iph> Time delay
3I0> Pickup
T 3I0> Time delay
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Iph> STUB Pickup
T Iph STUB Time delay
3I0> STUB Pickup
T 3I0 STUB Time delay
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Ip> Pickup
T Ip Time Dial
Time Dial TD Ip
T Ip Additional Time Delay
3I0p Pickup
T 3I0p Time Dial
Time Dial TD 3I0p
T 3I0p Additional Time Delay
IEC Curve
ANSI Curve
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Direction of stage Iph> Dir.
Iph> directional Pickup
T Iph> Dir. Time delay
Direction of stage 3I0> Dir.
3I0> directional Pickup
T 3I0> Dir. Time delay