Siemens SIPROTEC 7SD610 Manual page 401

Hide thumbs Also See for SIPROTEC 7SD610:
Table of Contents

Advertisement

No.
Description
181
Error: A/D converter (Error A/D-
conv.)
183
Error Board 1 (Error Board 1)
184
Error Board 2 (Error Board 2)
185
Error Board 3 (Error Board 3)
186
Error Board 4 (Error Board 4)
187
Error Board 5 (Error Board 5)
188
Error Board 6 (Error Board 6)
189
Error Board 7 (Error Board 7)
190
Error Board 0 (Error Board 0)
191
Error: Offset (Error Offset)
192
Error:1A/5Ajumper different from
setting (Error1A/5Awrong)
193
Alarm: Analog input adjustment
invalid (Alarm adjustm.)
194
Error: Neutral CT different from
MLFB (Error neutralCT)
196
Fuse Fail Monitor is switched
OFF (Fuse Fail M.OFF)
197
Measurement Supervision is
switched OFF (MeasSup OFF)
234.2100
U<, U> blocked via operation
(U<, U> blk)
285
Power factor alarm (cosϕ alarm)
289
Alarm: Current summation super-
vision (Failure Σi)
290
Alarm: Broken current-wire de-
tected L1 (Broken Iwire L1)
291
Alarm: Broken current-wire de-
tected L2 (Broken Iwire L2)
292
Alarm: Broken current-wire de-
tected L3 (Broken Iwire L3)
295
Broken wire supervision is
switched OFF (Broken wire OFF)
296
Current summation superv is
switched OFF (Σi superv. OFF)
297
Broken current-wire at other end
L1 (ext.Brk.Wire L1)
298
Broken current-wire at other end
L2 (ext.Brk.Wire L2)
299
Broken current-wire at other end
L3 (ext.Brk.Wire L3)
301
Power System fault
(Pow.Sys.Flt.)
302
Fault Event (Fault Event)
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
Function
Type
of In-
for-
matio
n
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Measurem.Superv
OUT
*
Measurem.Superv
OUT
on
off
Voltage Prot.
IntSP
on
off
Set Points(MV)
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
*
Measurem.Superv
OUT
*
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
P.System Data 2
OUT
ON
OFF
P.System Data 2
OUT
*
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
ON
*
ON
*
Appendix
A.8 Information List
IEC 60870-5-103
BO
135
178
1
Yes
BO
135
171
1
Yes
BO
135
172
1
Yes
BO
135
173
1
Yes
BO
135
174
1
Yes
BO
135
175
1
Yes
BO
135
176
1
Yes
BO
135
177
1
Yes
BO
135
210
1
Yes
BO
BO
135
169
1
Yes
BO
135
181
1
Yes
BO
135
180
1
Yes
BO
135
196
1
Yes
BO
135
197
1
Yes
BO
BO
BO
135
250
1
Yes
BO
135
137
1
Yes
BO
135
138
1
Yes
BO
135
139
1
Yes
BO
BO
BO
BO
BO
135
231
2
Yes
135
232
2
No
401

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents