Addr.
Parameter
3455
1.AR Tdead 3Flt
3456
1.AR Tdead1Trip
3457
1.AR Tdead3Trip
3458
1.AR: Tdead EV.
3459
1.AR: CB? CLOSE
3460
1.AR SynRequest
3461
2.AR: START
3462
2.AR: T-ACTION
3464
2.AR Tdead 1Flt
3465
2.AR Tdead 2Flt
3466
2.AR Tdead 3Flt
3467
2.AR Tdead1Trip
3468
2.AR Tdead3Trip
3469
2.AR: Tdead EV.
3470
2.AR: CB? CLOSE
3471
2.AR SynRequest
3472
3.AR: START
3473
3.AR: T-ACTION
3475
3.AR Tdead 1Flt
3476
3.AR Tdead 2Flt
3477
3.AR Tdead 3Flt
3478
3.AR Tdead1Trip
3479
3.AR Tdead3Trip
3480
3.AR: Tdead EV.
3481
3.AR: CB? CLOSE
3482
3.AR SynRequest
3483
4.AR: START
3484
4.AR: T-ACTION
3486
4.AR Tdead 1Flt
3487
4.AR Tdead 2Flt
3488
4.AR Tdead 3Flt
3489
4.AR Tdead1Trip
3490
4.AR Tdead3Trip
3491
4.AR: Tdead EV.
3492
4.AR: CB? CLOSE
3493
4.AR SynRequest
3601
O/U FREQ. f1
3602
f1 PICKUP
3603
f1 PICKUP
3604
T f1
3611
O/U FREQ. f2
3612
f2 PICKUP
3613
f2 PICKUP
3614
T f2
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
Function
C
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Frequency Prot.
ON: Alarm only
ON: with Trip
OFF
Frequency Prot.
45.50 .. 54.50 Hz
Frequency Prot.
55.50 .. 64.50 Hz
Frequency Prot.
0.00 .. 600.00 sec
Frequency Prot.
ON: Alarm only
ON: with Trip
OFF
Frequency Prot.
45.50 .. 54.50 Hz
Frequency Prot.
55.50 .. 64.50 Hz
Frequency Prot.
0.00 .. 600.00 sec
Setting Options
Default Setting
0.50 sec
1.20 sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
ON: Alarm only
49.50 Hz
59.50 Hz
60.00 sec
ON: Alarm only
49.00 Hz
57.00 Hz
30.00 sec
Appendix
A.7 Settings
Comments
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
Over/Under Frequency Protec-
tion stage f1
f1 Pickup
f1 Pickup
T f1 Time Delay
Over/Under Frequency Protec-
tion stage f2
f2 Pickup
f2 Pickup
T f2 Time Delay
393