Additional Specification L for Further System Interfaces (Port B)
Profibus DP Slave, electrical RS485
Profibus DP Slave, optical, 820 nm, double ring, ST connector
MODBUS, electrical RS 485
MODBUS, 820 nm, optical, ST connector
DNP 3.0, electrical RS485
DNP 3.0, optical, 820 nm, double ring, ST connector
IEC 61850, 100 Mbit Ethernet, double electrical, RJ45 connector
IEC 61850, 100 MBit Ethernet, optical, double, Duplex LC connector
1)
Not possible with surface mounting housing (position 9 = F). For the surface mounting version, please order a device
with the appropriate electrical RS485 interface and accessories as stated in Appendix A.1.2 „External converters".
2)
Not possible with surface mounting housing (position 9 = F).
see Additional Specification M
Additional Specification M for DIGSI/modem interface and protection data interface 1
Port C: DIGSI/Modem/Browser, electrical RS232
Port C: DIGSI/Modem/Browser, electrical RS485
Port D: FO5 optical, 820 nm, 2 ST connectors, length of optical fibre up to 1.5 km,
for FO direct connection or communication networks using multimode fibre
Port D: FO6 optical, 820 nm, 2 ST connectors, length of optical fibre up to 3.5 km,
for FO direct connection using multimode fibre
Port D: FO17 optical, 1300 nm, 2 LC duplex connectors, length of optical fibre up to 24 km,
for FO direct connection using monomode fibre
Port D: FO18 optical, 1300 nm, 2 LC duplex connectors, length of optical fibre up to 60 km,
for FO direct connection using monomode fibre
Port D: FO19 optical, 1550 nm, 2 LC duplex connectors, length of optical fibre up to 100 km,
for FO direct connection using monomode fibre
Port D: FO30 optical, 820 nm, 2 ST connectors, length of optical fibre up to 1.5 km,
for FO direct connection or communication networks with IEEE C37.94 via multimode fibre
1)
For surface-mounting housing (MLFB position 9 = F), delivery with external repeater
2)
This interface is only available in the flush-mounting housing (MLFB position 9 # F).
Three-pole tripping, without automatic reclosure
Three-pole tripping, with automatic reclosure
1-/3-pole tripping without automatic reclosure
1-/3-pole tripping with automatic reclosure
SIPROTEC, 7SD610, Manual
C53000-G1176-C145-6, Release date 02.2011
(only if Pos. 11 = 9)
1)
1)
Function Interface (Port C and D)
(device rear, port C and D)
1)
1)
1)
Functions 1
A.1 Ordering Information and Accessories
1)
2)
Appendix
Pos. 21
Pos. 22
0
A
0
B
0
D
0
E
0
G
0
H
0
R
0
S
Pos. 12
9
Pos. 23
Pos. 24
1
2
A
B
G
H
J
S
2)
Pos. 13
0
1
2
3