Power supply connection

+
Ø
Ø
Ø

Open Panel

Step 1
Step 2
Step 3
Step 1
Step 2
8
The Omnia8/L Panel is powered by the Mains source (230 V/50 Hz) through
an on-board power supply. The Mains wires must be connected to the termi-
nals (11) and the battery must be connected to the connectors (14).
On power up----the green LED
The red LEDs:
Battery
Fuse
Communicator
Communication Bus----will all go OFF.
On power up (Panel Open)----the OPEN LED on the keypad will go ON but the
Panel will not generate a Tamper Alarm. However, once the Panel is closed
a Tamper Alarm will be generated if the Panel is reopened.
The battery (13.8 V, 7 Ah max. not supplied) will supply the power during
mains failure. Mains failure will be signalled as follows:
The MAIN LED on the Panel will go OFF.
The TROUBLE LED on the Control Keypad will go ON.
Activation of one of the auxiliary outputs: 39[O1], 40[O2], 41[O3], 42[O4]----if
programmed to signal TROUBLE.
The cause of trouble must always be eliminated before the battery emp-
ties. Total power failure (mains and battery) will not affect the configuration,
as the non-volatile memory will save any changes made during Armed
status.
Access the programming phase before opening the Panel for servicing,
testing etc., as this will disable the tamper microswitch.
Enter INSTALLER PIN.
Press
to access programming.
Open the Panel.
or
Enter MAIN USER PIN.
Press
.
Main (on the Panel) will go ON.
Security System Control panel Omnia 8/L