Step
8.
Create a QoS policy and enter
its view.
9.
Associate a traffic class with a
traffic behavior in the QoS
policy.
10.
Return to system view.
11.
Enter ATM interface view or
ATM subinterface view.
12.
Enter PVC view or PVC view in
PVC-group.
13.
Apply the QoS policy to the
PVC.
NOTE:
For more information about traffic class, traffic behavior, and QoS policy, see
Configuration Guide

Configuring ATM OAM functions

Step
1.
Enter system view.
2.
Enter ATM interface view
or ATM subinterface view.
3.
Enter PVC view or PVC
view in PVC-group.
4.
Enable OAM F5
Loopback transmission
and retransmission
detection.
Enable OAM CC.
5.
Command
qos policy policy-name
classifier classifier-name behavior
behavior-name [ mode dcbx ]
quit
interface atm { interface-number |
interface-number.subnumber }
Enter PVC view:
pvc { pvc-name [ vpi/vci ] | vpi/vci }
Enter PVC view in PVC-group:
a.
b.
qos apply policy policy-name outbound
.
Command
system-view
interface atm { interface-number |
interface-number.subnumber }
Enter PVC view:
pvc { pvc-name [ vpi/vci ] |
vpi/vci }
Enter PVC view in PVC-group:
a.
pvc-group group-number
b.
pvc { pvc-name [ vpi/vci ] |
vpi/vci }
oam loopback interval [ up up-count
down down-count retry retry-interval ]
oam cc { both | sink | source }
pvc-group group-number
pvc { pvc-name [ vpi/vci ] |
vpi/vci }
143
Remarks
N/A
By default, a traffic class is
not associated with a
traffic behavior.
N/A
N/A
N/A
By default, no QoS policy
is applied to the PVC.
ACL and QoS
Remarks
N/A
N/A
N/A
By default, OAM F5 Loopback cell
transmission is disabled. Responses
are sent if an OAM F5 Loopback
cell is received.
By default, OAM CC is disabled.
When you configure OAM CC,
configure one end as source, and
the other end as sink.