Chapter 9 Validation
Builder
9-3 Validation Items List
Error
No.
1
Detect incorrect
addresses.
2
Detect unset addresses.
3
Check if a screen switch
object exists on each
screen.
4
Check if specified user
expansion DLL file exists.
5
Check if screen switch
destination exists.
6
Check if specified files
(BMP/TXT etc.) exist.
7
Check if total number of
addresses other than
common memory exceeds
the maximum limit for
each screen (2000).
8
Detect overlapping
functional objects.
9
Check if functional objects
are created inside
screen/frame area.
Item
Checks if the address format is incorrect or
if an address outside of the range has been
set.
Searches for functional objects or frames for
which an address has not been set.
Checks each screen for objects that switch
screens using command buttons.
Checks if the user derined DLL files
specified with either [Extensive setting] –
[User Function] for functional objects or
with user-defined objects are stored in the
Builder folder.
Checks if the screen switch destinations,
which are specified by screen switch buttons
created from command buttons, exist.
Checks if the files specified for functional
objects (BMP, JPG, CSV and, LST files)
exist in the screen storage folder. The screen
storage folder is automatically created 1
level below the project file, with the same
name as the project file name.
Checks each screen if the external
addresses are set to exceed 2000.
Checks if the functional objects overlap.
Checks if objects have been created in areas
that are not displayed while Run is
Running, and if objects created in frames
have been positioned in areas outside of the
frame.
9 − 4