Chapter 7 Run Parameter Setting
Builder
7-3 History Setting
Number
1)
Operation log history Sets the parameters of the operation log.
Log what
Record number of
history
Save in ring
buffer format
2)
Macro error log
history
Record number of
history
Save in ring
buffer format
Item
Selects from four types of operations can be logged:
Object's action, Screen switch, Execution of macro (Except
fix cycle), and Execution of macro (Fix cycle).
Sets the number of records to keep per file. Set within the
range of 0 to 1024 points.
If this option is checked when the number of records hits
the specified value in [Record number of history], a new
log that occurs is added to the same file, overwriting the
oldest log. The file name is "Operat.csv."
If the option is unchecked when the number of records
hits the specified value in [Record number of history], new
logs are recorded in a new file.
Sets the parameters for macro error log.
Sets the number of records to keep per file. Set within the
range of 0 to 1024 points.
If this option is checked when the number of records hits
the specified value in [Record number of history], a new
log that occurs is added to the same file, overwriting the
oldest error log. The file name is "MacroErr.csv."
If the option is unchecked when the number of records
hits the specified value in [Record number of history], new
logs are recorded in a new file.
7 - 5