Chapter 7 Run Parameter Setting
Builder
2. Display the [Device set] box.
Number
Item
1)
Layout points Select a point to be used for cyclic communications.
2)
Register
3)
Start No.
4)
End No.
5)
Target no.
6)
Register
7)
Start No.
8)
End No.
9)
Delete
3. After completing the layout settings for the device, click OK button.
7-6 Setting Cyclic Communications Range
If using words, select a point with 1 to 32 bits in a word.
If using bits, select a point with 16 to 512 bits. For bits, enter the
values as a multiple of 16.
Select CB or CW as the classification of the shared memory in
which files will be read/write to and from the MP2500 register.
Select the leading bit of the address for the shared memory, in
which files will be read/write to and from the MP2500 register.
If CB is selected as the register, enter the values as a multiple of
16.
Displays the last bit of the address, which is used to read/write
files to and from the MP2500 register.
If using the MP2500 register in slot 1, select 1. if using slot 2,
select 2.
Select CB or CW as (the classification of the shared memory in
which files will be read/write to and from the MP2500 register.
Select the leading bit of the address of the register, in which files
will be read/write to and from the shared memory.
For bit addresses, a bit number can only be set to zero (0).
Displays the last bit of the address, which is used to read/write
files to and from the shared memory.
Delete the setting in the selected line.