Dr Operation Of Iou Hot Replacement - Fujitsu PRIMEQUEST 2000 Series Administration Manual

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 5 Hot Maintenance in Red Hat Enterprise Linux 7
5.4 Hot replacement of IOU
*2: See the ETERNUS Multipath Driver User's Guide (For Linux).
FC card
1. Stop the access to FC card on IOU by such a way as stopping application.

5.4.2 DR operation of IOU hot replacement

This section describes the DR operation for IOU hot replacement.
1. Execute "/opt/FJSVdr-util/sbin/dr rm IOU" command on the shell of OS.
The IOU to be removed is cut off from OS.
Example: Cutting off the IOU 3
# /opt/FJSVdr-util/sbin/dr rm IOU3
#
2. Execute "/opt/FJSVdr-util/sbin/dr rm IOU" command on the shell of OS.
A list of IOU included in the partition is shown. Check that IOU which is cut off is displayed as 'offline'.
Example: Cutting off the IOU 3
# /opt/FJSVdr-util/sbin/dr stat IOU
IOU0: empty
IOU1: empty
IOU2: empty
IOU3: offline
3. Login to MMB console as administrator
4. Execute "hotremove" command on MMB console.
Example: removing IOU 3 from partition 1
Administrator > hotremove partition 1 IOU 3
Are you sure to continue removing IOU#3 from Partition#1?
[Y/N]: Y
DR operation start (1/3)
Remove IOU#3 (2/3)
IOU#3 power-off (3/3)
Removing IOU#3 from partition#1 has been completed
successfully.
Administrator >
5. See Operation Log window or perform "show dynamic_reconfiguration status" command and confirm
below messages.
Example: When removing IOU3 from partition 1.
Operation Log window:
"I_10110 Partition1 : Hot-remove IOU#3 Completed."
show dynamic_reconfiguration status:
"Removing IOU#3 from Partition#1, completed"
6. Pulling the IOU out from the slot of cabinet
For replacing IOU itself, insert PCI Express card mounted on old IOU to new one.
For replacing, expanding or removing PCI Express card on the IOU, do it now.
This step is performed by the field engineer in charge of your system.
7. Take off all cables such as LAN cable and FC cable connected to the IOU.
This step is performed by the field engineer in charge of your system.
8. Inserting IOU to the slot of the cabinet.
This step is performed by the field engineer in charge of your system.
9. Mount cables other than LAN cables.
This step is performed by the field engineer in charge of your system.
Note
In GLS configuration with NIC switching way, mount also LAN cables.
10. Execute "hotadd" command on MMB console.
Example: Adding IOU 3 to partition 1
158