Fc Card (Fibre Channel Card) Replacement Procedure - Fujitsu PRIMEQUEST 2000 Series Administration Manual

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 7 PCI Card Hot Maintenance in SUSE Linux Enterprise Server 12
7.7 Hot Replacement of PCI Express Cards
11. Check the status of replaced PCIC and click [Next].
12. Confirm that maintenance mode has been released (with information area of MMB Web-UI not gray out)
and click [Next].
Post-processing of software using a PCI Express card
After replacing a PCI Express card, restart the software stopped before the PCI Express card replacement or
make the software operation applicable again, as needed.

7.7.3 FC card (Fibre Channel card) replacement procedure

The descriptions in this section assume that an FC card is being replaced.
Notes
-
The FC card used for SAN boot does not support hot plugging.
-
This section does not cover configuration changes in peripherals (e.g., UNIT addition or removal for a
SAN disk device).
-
This manual does not describe how to change the configuration of peripherals such as expanding and
removing the unit of SAN disk device.
268
CA92344-0537-08

Advertisement

Table of Contents
loading

Table of Contents